Self Tests - HP 16530A Service Manual

Digitizing oscilloscope module
Table of Contents

Advertisement

HP 16530/31A- Service
6-7. SELF TESTS
The self tests for the
HP
16530/31 A Oscilloscope Module will identify the improper operation of
major functional areas in the module. They are not intended for component level diagnostics. If
there are multiple oscilloscope modules, the user must select the specific oscilloscope module
to be tested at the main test system menu.
All self tests can be run without access to the interior of the instrument. If a failure is found, the
troubleshooting chart in paragraph 6-8 may require the use of the extender board to further iso-
late the problem to a specific card or cable.
SELF TEST ACCESS PROCEDURE:
This procedure uses the Acquisition Mem Test as an example. During troubleshooting, any or all
tests can be used.
a.
Disconnect all oscilloscope inputs and turn power switch on.
b.
From the startup screen shown in figure
6-4, touch Configuration field, then touch Test.
.___...sy,_s_te_m _
_.,) (conr
i
gure
tt
on)
Cards
A
B
C SCOPE ACQUISITION
400 MEGASAMPLE/s
E
SCOPE TIMEBASE
400
MEGASAMPLE/s
Figure 6-4. Startup Screen
Controller
RS-232C
Printer
6-5