Installation Of Remote Condenser Unit; Checks Before Installation; Location - Hoshizaki KMD-850MAH Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KMD-850MAH:
Table of Contents

Advertisement

F. Installation of Remote Condenser Unit

1. Checks Before Installation

1) Remove the shipping carton, tape, and packing material.
) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade moves freely.

2. Location

The remote condenser unit is intended for outdoor use. Normal operating
ambient temperature should be within -0°F to +1°F (-9°C to +50°C).
Operation of the remote condenser unit, for extended periods, outside of this
normal temperature range may affect icemaker performance.
The remote condenser unit must be positioned in a permanent site under the following
guidelines:
• A firm and flat site.
• A dry and well ventilated area with 4" (61 cm) clearance in both front and rear for ease of
maintenance and service should they be required.
• The maximum line length for the standard refrigerant charge is 66 feet. Should an
installation require a longer line length, additional refrigerant must be added to the
system. Add .4 oz. of R-404A for each foot over 66 feet to a maximum of 100 feet or call
1-800-33-1940 for recommendations.
• The maximum vertical distance between the remote condenser unit and the icemaker is
33 feet above or 10 feet below the icemaker. These distances are measured fitting to
fitting.
Failure to install the equipment within these guidelines may adversely affect
performance, component life, and warranty coverage.
IMPORTANT
CAUTION
Min. 4" (61 cm) Clearance
Air
Air
Locate
Legs
Fig. 4
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmd-850mrhKmd-850mwh

Table of Contents