SEAL CHAMBER CLEANING
.
8
Locate BEARING
LOCK WASHER and
pry TAB up clearing
the RETAINING
RING.
NOTE: TAB may not
be in locked the 0º
position and may
be reinstalled in
any of the 8 locking
positions.
.
10
With RETAINER RING removed
Remove foreign matter.
Replace LIP SEAL if necessary
Fluid ports can be checked
and cleaned.
NOTES AFTER NEW SEAL INSTALLATION:
RETAINER RING is tightened to 1/8 turn after snugged.
Refill lubrication reservoir with 32Oz. of lubrication
fluid. (Royal Purple FDA 46 or similar). SEE SENTRY
STARTUP AND FLUSH PROCEDURE. Pg. 11
For Jensen Mixer Parts - Call 281-350-1200
11
REMOVE BELT HOUSING COVER
11
MECHANICAL SEAL stationary pin should be
in contact with either anti-rotation pins
located at the 3 or 9 O'clock position in
the seal chamber.
.
9
Partially thread
in 1/4-20 bolts
(shown with
arrows) to aid in
turning

RETAINING RING

with screwdriver.
UNSCREW BY
TURNING TO
LEFT 4-5
ROTATIONS
.
Install NEW
MECHANICAL
SEAL noting the
stationary pin
on SEAL.