10.1.2. Adjustments
Adjust driver section voltages referring the panel data on the panel data label.
Name
Test 
Point
Vsus
TPVSUS 
Vsus ± 2V
(SS)
Ve
TPVE 
Ve ± 2V
(SS)
Vset
TPVSET 
232V ± 7V
(SC)
Vad
TPVAD 
-90V ± 1V
(SC)
Vscn
TPVSCN 
Vad+125V 
(SC)
± 4V
Vda
TPVDA 
70V ± 1V
(SS)
Vdat
P12-1, 5 
70.2V ± 
(P)
0.1V
PFC
C446 (+)
396V ± 0.5V R443 (P)
(-)
Vlow
C555 (+)
73.0V ± 
(-)
0.1V
Csus
TPVSUS 
165V ± 0.5V R671 (P)
/ (SS)
*See the Panel label.
10.2. Initialization Pulse Adjust 
1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
Picture menu : Vivid
Voltage
Volume
R628 (P)
VR6000 
(SS)
Fixed
VR6600 
(SC)
Fixed
Fixed
R665 (P)
R661 (P)
Remarks
*
*
Vda load 
current : 
0.4A
Vsus load
 
current : 
1.25A