Overview

Overview
The Cisco Nexus 93180YC-FX3 switch (N9K-C93180YC-FX3) is a 1-rack unit (RU), fixed-port switch
designed for spine-leaf-APIC deployment in data centers. This switch has the following ports:
• 48 100M/1/10/25-Gigabit Ethernet SFP28 ports (ports 1-48).
• 6 10/25/40/50/100-Gigabit QSFP28 ports (ports 49-54)
• One management port (one 10/100/1000BASE-T port)
• One console port (RS-232)
• 1 USB port
This switch includes the following user-replaceable components:
• Fan modules (four) with the following airflow choices:
Overview, on page 1
• Port-side exhaust fan module with blue coloring (NXA-FAN-35CFM-PE)
• Port-side intake fan module with burgundy coloring (NXA-FAN-35CFM-PI)
Note
This switch runs with +1 redundancy mode, so that if one fan fails, the switch
can sustain operation. But if a 2nd fan fails, this switch is not designed to sustain
operation. Hence before waiting for major threshold temperature to be hit, the
switch will power down due to Powered-down due to fan policy trigger.
Note
Each fan module has two rotors. The switch can function normally if one rotor
inside the any one fan module fails. In case of more than one rotor failure, the
switch will issue a warning and power down in 2 minute.
Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide