Installation Of Indoor Unit - Gree GWH09AECXB-K6DNA1A Service Manual

Table of Contents

Advertisement

Service Manual
the following table. Air switch should be included magnet buckle
and heating buckle function, it can protect the circuit-short and
overload. (Caution: please do not use the fuse only for protect the
circuit)
Model
09/12K

8.5 Installation of Indoor Unit

1. Choosing Installation Iocation
Recommend the installation location to the client and then confirm
it with the client.
2. Install Wall-mounting Frame
(1) Hang the wall-mounting frame on the wall; adjust it in
horizontal position with the level meter and then point out the
screw fixing holes on the wall.
(2) Drill the screw fixing holes on the wall with impact drill (the
specification of drill head should be the same as the plastic
expansion particle) and then fill the plastic expansion particles in
the holes.
(3) Fix the wall-mounting frame on the wall with tapping screws
and then check if the frame is firmly installed by pulling the frame.
If the plastic expansion particle is loose, please drill another fixing
hole nearby.
3. open piping hole
(1) Choose the position of piping hole according to the direction of
outlet pipe. The position of piping hole should be a little lower than
the wall-mounted frame,shown as below.(As show in Fig.1)
300
55
(2) Open a piping hole with the diameter of Φ55mm on the
selected outlet pipe position. In order to drain smoothly, slant the
piping hole on the wall slightly downward to the outdoor side with
the gradient of 5-10°.(As show in Fig.2)
Indoor
5-10
Note:
Pay attention to dust prevention and take relevant safety
measures when opening the hole.
Installation and Maintenance
Air switch capacity
Power cord
10A
3G1.0
Fig.1
Outdoor
Φ55mm
°
Fig.2
4. Outlet Pipe
(1) The pipe can be led out in the direction of right, rear right, left
or rear left.(As show in Fig.3)
(2) When selecting leading out the pipe from left or right, please
cut off the corresponding hole on the bottom case.(As show in
Fig.4)
(3) Selection of drainage outlet and drainage installation and
disassembly guide
● Please determine the position of drainage outlet before
installation the drainage pipe.
● Suggestion for selection of drainage outlet: there are no
mandatory requirements for the direction of the drainage pipe.
However, it's suggested to be same with the direction of liquid pipe
and gas pipe. Therefore, you are suggested to select the drainage
outlet which is close to the exit tube:
① Take out the drainage pipe from the carton box.
② Pull out the rubber stopper of drainage outlet with pliers or
other tools.
300
55
③ Install drainage pipe.
Hold the head of drainage pipe (20cm away from the drainage
pipe outlet) with hand and install it along the direction of drainage
outlet until you have head a sound.
Fig.3
Fig.4
35

Advertisement

Table of Contents
loading

Table of Contents