2.3 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.

2.4 Noise Curve

Indoor side noise when blowing
45
40
12K Heating
35
12K Cooling
30
25
20
SL
L
Indoor fan motor rotating speed
8
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09/12K
0.8 ~ 1.1
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09/12K
2.8 ~ 3.2
09K Heating
09K Cooling
ML
M
MH
H
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
12 to 15
65 to 38
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
35 to 63
2 to 5
60
58
56
54
52
50
48
46
SS
20
30
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBO
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBO
High
Heating
Cooling
40
50
60
70
80
Compressor frequency(Hz)
Technical Information
Service Manual
Compressor
revolution (rps)
49
Compressor
revolution (rps)
59
90
100