2.2

Recommended Equipment for Testing

2.2.1
Power Supplies
Power Supply #1 (PS#1): a power supply capable of supplying 20 V at 1 A
2.2.2
Loads
A 20-V (or above), 1-A (or above) electronic load that can operate at constant current and constant
voltage mode or equivalent
2.2.3
Meters
Four Fluke 75 multimeters, (equivalent or better) or two equivalent voltage meters and two equivalent
current meters. The current meters must be capable of measuring 1 A + current.
2.3

Recommended Test Equipment Setup

1. Set the power supply #1 (PS#1) for 6.5 V ± 200 mVDC, 1-A ± 0.1-A current limit, and then turn off
supply.
2. Connect the output of PS#1 in series with a current meter (multimeter) to J1 (VBUS, GND).
3. Connect a voltage meter across J1 (VBUS, GND).
4. Connect Load #1 in series with a current meter to J2 (VBAT, GND). Turn off Load #1.
5. Connect a voltage meter across J2 (VBAT, GND).
6. Check all jumper shunts. JP1: OFF; JP2: OFF; JP3: OFF; JP4: OFF; JP5: connect 1-2 (External TS);
JP6: connect 2-3 (VBUS); JP7: connect 1-2 (charger OFF/ MODE high).
Power supply
Iin
#1
SLUU477B – December 2010 – Revised November 2015
Submit Documentation Feedback
BQ24210 EVM
HPA678
J1
I
GND
V
VBUS
JP1
J4
JP4
JP5
Figure 1. Original Test Setup for HPA678 (bq24210/2EVM)
Copyright © 2010–2015, Texas Instruments Incorporated
J2
BAT
GND
TS
U1
APPLICATION CIRCUIT
LED
CHG
PG
D1
D2
JP7
JP6
JP2
800-mA, Single-Input, Single-Cell, Li-Ion Battery Solar Charger
Test Summary
I
Load #1
IBAT
V
JP3
J3
5