1.4

Jumper Settings

Jack
Description
JP1
Programs the fast-charge current setting. 500 mA when JP1 ON; external setting
when JP1 OFF
JP2
Connect /EN and /PG together when JP2 ON to enable charger when power present
JP3
Programs the input voltage regulation threshold. 4.5V when JP3 ON; external setting
when JP3 OFF.
JP4
Limited power charge mode (LPCM) when JP4 ON; normal operation when JP4 OFF Jumper OFF (normal operation)
JP5
Select external TS input or internal TS setting
1-2 : External TS input
2-3 : Internal TS setting
JP6
The pullup power source supplies for the LEDs
1-2 : BAT
2-3 : VBUS
JP7
Charger EN / MODE
1-2 : OFF/HIGH
2-3 : ON/LOW
1.5

Recommended Operating Conditions

Supply voltage, V
BUS
Battery voltage, V
BAT
Supply current
Charge current, I
chrg
Operating junction temperature
range, T
J
An external resistor is used to program the VBUS_DPM. The programming resistor, R
the following equation:
(
VBUS_
R
=
VDPM
Where:
VBUS_
is the desired input voltage regulation voltage threshold.
DPM
VBUS_
is the built-in offset threshold, nominally 3.5 V.
DPM_1
K
is a gain factor found in the electrical specification.
VBUS_DPM
If VDPM pin is shorted to VSS; the VBUS_
If the VDPM pin is floated (open circuit), the IC operates in Battery Tracking mode. In this case, VBUS
DPM threshold is internally set as V
V).
Connecting JP3 set 4.5 V VDPM on EVM.
An external resistor is used to program the output current (50-800 mA). The equation for charge current is:
K
ISE T
R
=
ISET
I
O UT
Where, I
is the desired fast-charge current; K
OUT
The termination and precharge current are internally set at 10% and 20% of fast-charge current,
respectively. The precharge-to-fast-charge, V
Connecting JP1 set 500 mADC for fast-charge current and 100 mADC for precharge current on EVM.
SLUU477B – December 2010 – Revised November 2015
Submit Documentation Feedback
Table 2. Jumper Settings
Table 3. Recommended Operating Conditions
Description
Input voltage
Voltage applied at VBAT terminal of J2
Maximum input current
Battery charge current
)
-
VBUS_
DPM
DPM_ 1
KVBUS_
DPM
DPM
, which is BAT + 100 mV. (BAT > 3.65 V) or 3.75 V (BAT ≤ 3.4
TRK
ISET
threshold is set to 2.5 V.
lowv
Copyright © 2010–2015, Texas Instruments Incorporated
Min
Typ
4.5
0
0
0
0
must be clamped to 3.65 V.
is a gain factor found in the specification.
800-mA, Single-Input, Single-Cell, Li-Ion Battery Solar Charger
Introduction
Factory Setting
Jumper OFF (external setting)
Jumper OFF (external /EN)
Jumper OFF (external setting)
Jumper ON 1-2 (external TS)
Jumper ON 2-3 (VBUS)
Jumper ON 1-2 (charger OFF /
MODE High)
Max
Unit
Notes
7.3
V
4.2
V
0.8
A
0.8
A
125
°C
is dictated by
VDPM
(1)
(2)
3