4" Adjustable Legs (GRS Models)
NOTE: 4" (102 mm) legs are standard on models
42" (1067 mm) and wider.
Carefully lay unit on its side. Install legs to bottom of
unit (see Figure 14). Hand-tighten legs until snug.
Do not over-tighten. Return unit to the upright
position.
NOTICE
Do not lay unit on the side with the control panel
or damage to unit could occur.
Leg Adjustment
Shorten
Lengthen
Figure 14. Leg Installation
NOTE: Legs are adjustable for leveling the unit.
Use a 9/16" (14 mm) open-end wrench to
make leveling adjustments once the unit is
placed in final position.
Remote Mounted Control Panels
(GRSB and GRSBF models)
Two flush-style remote mounted control panels are
available for the GRSB and GRSBF units — the
mechanical Thermostat Control panel and the digital
Indicating Temperature Control (ITC) panel. Both
control panels are installed using the following
procedure.
4-3/4"
(121 mm)
A
D
C
Figure 15. Remote Mounted Control Panel Installation Dimensions
ELECTRIC SHOCK HAZARD: The remote
mounted control panel must be mounted on a
vertical wall and installed in the vertical
position. Mounting the control panel in the
horizontal position may result in the collection
of liquids and lead to an electric shock.
The remote mounted control panel should be
installed outside of the heat zone. Locating the
control panel inside the heat zone will cause the
control(s) to overheat, malfunction, and fail. See
Figure 11 for maximum mounting distances.
Do not modify wiring or cut thermostat capillary
wire on control box to increase semi-remote
mounting distance. Cutting the thermostat
capillary wire will cause the unit to overheat and
may damage the unit as well as the surrounding
countertop.
NOTE: A qualified electrician is recommended for
connecting the units to a power source.
1. Prepare cutout and pre-drill screw holes (see
Figure 15).
2. Remove
trim
assembly.
3. Position control panel into opening through the
backside.
4. Secure control panel to surface using screws
(not supplied).
5. Connect proper power source to the mounted
remote control panel.
6. Reinstall trim cover.
NOTE: Units
are
(914 mm) flexible conduit connecting the
control panel to the unit.
Cutout
Dimension
5-7/8"
B
(149 mm)
6-3/8"
(162 mm)
18
WARNING
NOTICE
cover
from
control
equipped
with
Screw Hole
Dimension
(A)
(C)
3-7/8"
(98 mm)
(B)
(D)
6-3/4"
(171 mm)
Form No. GRSM-0108
panel
a
36"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents