Glo-Ray Buffet Warmers are shipped with most
components pre-assembled. Care should be taken when
unpacking shipping carton to avoid damage to unit and
components enclosed.
1. Remove the unit from the carton.
2. Remove all tape and packing materials.

LEGS

CAUTION
The National Sanitation Foundation (NSF) requires
units over 36" (91 cm) in length or weighing more
than 80 lbs. (36 kg) to be either sealed or raised on
the installation surface. If this unit cannot be sealed
at the point of use, 4" (10 cm) legs are included to
allow for proper cleaning access below unit. See
Hatco ACCESSORIES for installation instructions.
1. Carefully lay unit on its side.
CAUTION
Do not lay unit on the side with the control panel or
damage to unit could occur.
2. Install metal leg into each corner hole on base.
Tighten securely. Place a rubber foot onto each leg.
See Figure 3.
3. Turn unit upright and position warmer in
desired location.

BREATH PROTECTORS

Acrylic breath protectors shield the food while allowing
easy access to the food product. Specially designed
housings and mounting hardware make installation simple.
NOTE: Remove protective paper from acrylic surfaces
before mounting breath protector.
1. Slide the weld screws into the slot as shown in
Figure 4. Place weld screws into approximate
position to align with holes in breath protector.
2. Carefully position breath protector and "L" channel
so holes align with weld screws, then install so weld
screws protrude through holes.
3. Secure "L" channel and breath protector to weld
screws using cap nuts provided.
Figure 3. Installing Legs.
Weld Stud
Figure 4. Installing Breath Protector.

LOCATION

For safe and proper operation, the unit must be
located a reasonable distance from combustible walls
and materials. If safe distances are not maintained,
discoloration or combustion could occur.
Locate the unit at the proper counter height, in an
area that is convenient for use. The location should
be level to prevent the unit or its contents from
accidentally falling, and strong enough to support
the weight of the unit and food displayed.