INSTRUCTION MANUAL
NAMRON THERMOSTAT
TOUCH ZIGBEE 16A

Advertisement

loading

Summary of Contents for Namron ZIGBEE 16A

  • Page 1 INSTRUCTION MANUAL NAMRON THERMOSTAT TOUCH ZIGBEE 16A...
  • Page 2: Technical Data

    INSTRUCTION MANUAL Namron termostat touch ZigBee 16A 81mm 28.4mm 21.3mm Technical data ZigBee Frequency 2.4GHz Operation voltage 220-240V~50/60Hz Maximum load Power consumption <2W Ambient temperature 0°C to 40°C (during operation) Temperature range 0°C to 40°C Hysteresis 0.5°C to 2°C (default 0.5°C) Floor sensor NTC R25=10K±1%@25°C, B25/50=3950K±1%, (3m included)
  • Page 3: Installation

    Installation a.Installation must be done by a qualified electrician. b.Power supply must be turned off during installation. (1) Wiring diagram 4512737 NT C L N N Floor temp sensor (2) Mounting Remove the display unit and front cover by using a small screwdriver. Insert the wires to the correct terminals as presented in the wiring diagram above.
  • Page 4 Time Setting Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow: Short press button to select the item would like to modify, then short press move up and move down buttons to modify value of selected item, then short press button to save and quit, short pressing button only quits without saving.
  • Page 5 Schedule setting method 2: on System Setting Interface, meanwhile the device is under Auto Mode , short press button to enter into Auto Mode Schedule weekly setting interface quickly: On Auto Mode Schedule weekly setting interface, use buttons to enter into schedule setting of a certain week as follows: On Auto Day Schedule interface, short press button to select the time or temperature that...
  • Page 6 The function of monitor set is real time monitor of over current, over heat and freezing. On Home Interface, short press MONITOR SET to enter into monitor set interface a s follows: Short press button to select the item would like to modify, then Monitor Set short press move up and down buttons to modify value of selected item, then short press...
  • Page 7 On the Home Interface, press and hold both buttons for over 10S, during the process, the icon will flash slowly, the Display Display Auto OFF function can be enabled or disabled, when the Auto Off function is enabled, the icon will be displayed, otherwise the icon will not be displayed.
  • Page 8 Zigbee Configuration Introduction Select Network Set on Home Interface to enter into Zigbee network management interface as follow: Adding to a Zigbee Network Operate your Zigbee gateway to add device, select “Add”, then short press button , the device will search network and try to join, “Status”...
  • Page 9 INT8U , StackVersion 0x0002 read-only INT8U , HWVersion 0x0003 Hardware version 1 read-only string, ManufacturerName 0x0004 read-only “NAMRON AS” ModelIdentifier string, 0x0005 read-only “4512737 & 4512738” DateCode string, 0x0006 NULL read-only PowerSource ENUM8, 0x0007 Device power supply, fixed value 0x01 Mains (single phase)
  • Page 10 ENUM8, GenericDevice-Class 0x0008 read-only 0XFF GenericDevice-Type ENUM8, 0x0009 read-only 0XFF ProductCode octstr 0x000A read-only ProductURL string, 0x000B NULL read-only Sw build id string, 0x4000 6.9.1.0_r4 read-only Command supported: Command Description Reset to Factory Defaults Command On receipt of this command, the device resets all the attributes of all its 0x00 clusters to their factory defaults.
  • Page 11 Store Scene 0x04 Stores the device’s current state as a scene or updates a previously stored scene accordingly Recall Scene 0x05 Reverts the device’s current state using the values from the previously stored field set. 5.2.3 Groups-0x0004 (Server) Attributes supported: Type Description Attribute...
  • Page 12 Enum8, ControlSequenceOfOperation 0x001B reportable Set device supported operation type, here only supports Heating Only(0x02) Map16, HVAC relay state/ ThermostatRunningState read-only, 0x0029 Indicates the relay on/off status, here only supports bit0( Heat State) reportable Proprietary Attributes: Manufacturer Type Description Attribute code OperateDisplayLcdBrightnesss OLED brightness when operate the buttons: ENUM8,...
  • Page 13 Hysterersis INT8U Hysterersis setting, range is 5-20, unit is 0.1ºC, default value 0x100A 0x1224 reportable is 5 DisplayAutoOffEnable ENUM8 0, disable Display Auto Off function 0x100B 0x1224 reportable 1, enable Display Auto Off function AlarmAirTempOverValue INT8U, 0x2001 0x1224 Room temp alarm threshold, range is 0.20-60, unit is 1ºC, reportable 0 means disabled, default is 45 Away Mode Set:...
  • Page 14 int16S , ActivePower reportable 0x050B Single phase valid power, unit is W read-only int16U, ACVoltageMultiplier 0x0600 read-only ACVoltageDivisor int16U, Used together with above attributes, the real displayed voltage = 0x0601 read-only RMSVoltage* ACVoltageMultiplier / ACVoltageDivisor int16U, ACCurrentMultiplier 0x0602 read-only ACCurrentDivisor int16U, Used together with above attributes, the real displayed current = RMSCurrent 0x0603...
  • Page 15 5.2.9 OccupancySensing-0x0406(client) The attributes that can be received: Type Description Attribute Occupancy Bit 0 specifies the sensed occupancy as follows: 1 = occupied, 0 = unoccupied. bitmap8 , 0x0000 This flag bit will affect the Occupancy attribute of HVAC cluster, and the operation mode.
  • Page 16 Namron AS Nedre kalbakkvei 88B 1081 Oslo Norway post@namron.com...