INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Namron TOUCH Z-WAVE 16A

  • Page 1 INSTRUCTION MANUAL...
  • Page 2: Technical Data

    INSTRUCTION MANUAL Namron termostat touch Z-Wave 16A 81mm 28.4mm 21.3mm Technical data Z-Wave frequency 868.42MHz (EU) Operation voltage 220-240V, 50/60Hz Maximum load Power consumption <2W Ambient temperature 0°C to 40°C (during operation) Temperature range 0°C to 40°C Hysteresis 0.5°C to 2°C (default 0.5°C) Floor sensor NTC R25=10K±1%@25°C, B25/50=3950K±1%, (3m included)
  • Page 3: Installation

    Installation a.Installation must be done by a qualified electrician. b.Power supply must be turned off during installation. (1) Wiring diagram 4512744 S R - Z V 9092A NT C L N N Floor temp sensor (2) Mounting Remove the display unit and front cover by using a small screwdriver. Insert the wires to the correct terminals as presented in the wiring diagram above.
  • Page 4: Settings Menu

    Settings Menu Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow: Enter settings menu (needs to be added) 1. Under Home Interface, meanwhile the device is at OFF mode (Off icon), press and hold up and down buttons at the same time for over 5 seconds to enter Settings Menu.
  • Page 5 Schedule setting method 1: user can enters into schedule on Z-Wave Set Interface, the schedule interface is as follows: Short press button to select “Auto Schedule”, then short press button Schedule weekly setting interface. Schedule setting method 2: on Home Interface, meanwhile the device is under Auto Mode , short press button to enter into Auto Mode Schedule weekly setting interface quickly: On Auto Mode Schedule weekly setting interface, use buttons...
  • Page 6 The function of monitor set is real time monitor of over current, over heat and freezing. On Home Interface, short press MONITOR SET to enter into monitor set interface a s follows: Short press button to select the item would like to modify, then Monitor Set short press move up and down buttons to modify value of selected item, then short press...
  • Page 7 Select OTHER SET on Home Interface to enter into OTHER SET interface as follow: Short press button to select the item you would like to modify, Other Set then short press move up and down buttons to modify value of selected item, then short press button to save and quit, short pressing...
  • Page 8 Z-Wave Set Introduction 1 .Z-Wave Network Management Select ZWAVE INFO on Home Interface to enter into Z-Wave network management interface as follow: Adding to a Z -Wave Network ( Inclusion) Method 1: Select “Add”, then short press button , the device will send out inclusion request, “Status” will show “Inclusion...”. If there is no response from a gateway within 30 seconds, or inclusion failed, “Status”...
  • Page 9 Thermostat Related Specifications Command Support ThermostatMode_OFF(off) ThermostatMode_HEAT(UI displays Manual) ThermostatMode ThermostatMode_DRY ThermostatMode_EnergyHeat(UI displays Auto) ThermostatMode_Away(UI displays Away) ThermostatSetPoint ThermostatSetPointType_Heating(set manual temperature) ThermostatSetPointType_Energy_Save_Heating(set auto temperature) ThermostatSetPointType_DRY ThermostatSetPointType_Away_Heating(set away temperature) 3. Supported Command Class Root Device Suppourt Command class Support S2/s0 COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_TRANSPORT_SERVICE...
  • Page 10 Note: the EndPoint01 mirrors equivalent effect root endpoint. EndPoint1 command list: Support command class Support S2/s0 COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION OMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STATE COMMAND_CLASS_THERMOSTAT_SETPOINT EndPoint2 (floor temperature sensor) command list: Support command class Support S2/S0 COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SENSOR_MULTILEVEL...
  • Page 11 EndPoint01 : Group ID NAME Profile Max nodes Description AGI_LIFE_LINE Lifeline Lifeline(0x0001) (0x0001) Note: the EndPoint01 has equivalent effect of root function. EndPoint02 Group ID NAME Profile Max nodes Description AGI_LIFE_LINE Lifeline Lifeline(0x0001) (0x0001) 6.Advance Config Parameters Default Parent Parameter Size Description Value...
  • Page 12 Time interval value for periodic report of temperature, humidity, unit is S 0, disable to report 0x11(17) None (5mins) 30~28800, report when time interval value is 30~28800 When to report power change absolute threshold, unit is W 0, disable to report 0x12(18) None 1~100, report when absolute threshold is 1~100...
  • Page 13 Namron AS Nedre kalbakkvei 88B 1081 Oslo Norway post@namron.com...