Mitsubishi Electric KD Series User Manual page 56

Contact image sensor (cis)
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

3-2-1 Preparation by users
⑩ DC5V cable connecting CIS-Optional PSU
Connecting to Optional PSU,
DAU-15P-F0R(JAE) for the housing on cable
030-50635 (JAE) for the contact pin is recommended.
Optional PSU has,
DALC-J15SAF-13L6ER(JAE) for the connector,
Connecting to CIS,
DAU-15S-F0R(JAE) for the housing on cable
030-50634(JAE) for the contact pin is recommended.
CIS has,
DAU-15P-F0R(JAE) for the connector,
030-50635(JAE) for the contact pin.
【Remarks】
When you use a cable in the field as the power cable,
confirm the connection and the cable length and standard
carefully.
Cable resistance 120mΩ or less between the power supply
and CIS is recommended.
(Cable standard AWG22: approx. 2m, AWG20: approx.
3m, AWG18: approx. 5m)
TM-XH719C
3-2 Preparation
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Pin assignments of Optional PSU and CIS connectors are
shown below.
Name
Optional
I/O
No
PSU
connection
1
O
GND
2
3
O
+5V
4
5
O
GND
6
7
O
+5V
8
9
O
GND
10
11
O
+5V
12
O
13
GND
O
14
+5V
-
15
NC(GND)
Set the pairs of +5V and GND as follows, when you connect
pins.
1 pin and 9 pin, 2 pin and 10 pin, 3 pin and 11 pin,
4 pin and 12 pin, 5 pin and 13 pin, 6 pin and 14 pin,
7 pin and 15 pin
The same pin assignment of V1 can be applied with the pin
assignment of V3.
Name
CIS
I/O
No
Symbol
connection
V1 (V3)
1
GND
2
3
VDD
4
+5V
5
GND
6
7
VDD
NC
8
9
GND
10
11
VDD
12
GND
13
GND
14
VDD
-
15
Symbol
I
VDD
-
-
I
GND
56

Advertisement

Table of Contents
loading