OPERATION

REFUELLING PUMP

Do not bring fire or sparks near the fuel.
1. When the machine is operated on sites with no fuel con-
tainer and pump, the machine may be refuelled using the
refuelling pump (if fitted) from fuel barrels.
The refuelling pump is located under the air cleaner at the
right hand side of the machine.
2. Place the fuel hose (2), which is stored in tray (3) into the
fuel barrel placed next to the fuel tank.
3. Switch on refuelling pump using switch (1) on the pump
assembly when adding fuel, never let the fuel overflow.
This may cause a fires.
NOTICE
q
This pump is protected by a fuse (2). If pump fails to
function check fuse (10A).
q
Ensure strainer on hose end is clean.
WARNING
DETAILED CONTROLS AND GAUGES
2
3
2
1
9JH02623AA
3-109