3-2. BEFORE ADJUSTMENT
Note:
1.
Before adjustment, connect the equipments referring to
"3-1-2. Connection".
2.
Before adjustment, Turn on POWER switch and allow for
10-minute warm-up time.
3-2-1.
Color Bar Signal Confirmation
Equipment:
Vectorscope, Waveform monitor
Preparation:
OUTPUT/DL/DCC + switch/camera side
Test point:
VIDEO OUT connector/camera side
Specification:
[for NTSC]
• Chroma Level
Confirm that the beam spots of each color (R, YL, G, CY, G,
B and MG) are inside the "4" mark.
[for NTSC]
Burst Spot 75%
Burst Spot 75%
R
M
G
Y
L
G
C
Y
Note:
• Partial difference between scale and signal level is caused
by photographic error.
• If the specifications are not met, carry out from "3-3-2. INT
SC Phase Adjustment" through "3-3-9. Chroma (YC) Level
Adjustment".
→ BARS
[for PAL]
[for PAL]
R
M
G
Y
L
B
B
G
C
Y
3-2-2.
Sensitivity Measurement Confirmation
Object:
Overall white
Light:
3200K, 2000 lux
(If the pattern box is used, set the AUTO
mode)
Preparation:
1. Adjust the zoom control at "TELE" so that the white pattern
frame matches the underscanned picture frame on the
screen.
2. Lens iris
3. OUTPUT/DL/DCC + switch/camera side → CAM
4. WHITE BAL switch/camera side
Equipment:
Waveform monitor
100 ± 10 IRE (for NTSC)
Specification:
700 ± 70 mV (for PAL)
[for NTSC]
Note:
If the specification is not met, perform "3-3-11. CCD OUT
Level Adjustment".
3-4
→ F11
→ PRESET
[for PAL]
DXC-D30 (UC)
DXC-D30P (CE)