Operation Details
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
• Fan speed rotates in the range of Hi to Me.
• Deodorizing Control.
Indoor
Fan
Comp.
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
Cooling Operation Time Diagram
Intake Air
Temperature
Set Temp.
Outdoor Air
Temperature
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
4 Way Valve
2 Way Valve (A241K)
<Description of operation>
d – g
:
Time Delay Safety Control (waiting for 3 minutes)
g – h
:
60 sec. Forced Operation
h – o
:
7 min. Time Saved Control
q – t
:
Anti Freezing Control
v – y
:
Outdoor Fan Control
. .
. .
1
SLo
stop
stop
40"
30"
ON
a b c d e f g h i j k l m n o p q r s t u v w x y z
Comp.
ON
1.5˚C
Comp.
OFF
31˚C
29˚C
1'
3'
SLo
SLo
SLo
stop
stop
20"
160"
40"
30"
OFF
ON
Indoor
10°C
Heat
Exchanger
Temp.
2°C
1'
7'
1'
4'
Hi