BASIC SERVICE

Regular cleaning of the elements in the optical path, as well as the air vents, is vital to
maintaining the operational quality of the PLLEDC64ALN.
Important! Excessive dust, smoke fluid, and particulate build-up degrades performance and
causes overheating and damage to the fixture that is not covered by the warranty.
Cleaning the air vents:
To maintain adequate cooling, dust must be cleaned from the air vents periodically. Remove
dust from the air vents with a soft brush, cotton swab, vacuum, or compressed air.
Cleaning optical components:
Clean the optical components regularly. The presence of smudges or dust on optical surfaces
can reduce the strength of the light output and the quality of the effects.
Use care when cleaning optical components and work in a clean, well lit area. The coated
surfaces are fragile and easily scratched. Do not use solvents that can damage plastic or
painted surfaces.
Disconnect the fixture from power and allow it to.
Remove upper cover.
Vacuum or gently blow away dust and loose particles with compressed air.
Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner
or distilled water. Do not rub the surface: lift the particles off with a soft repeated press.
Remove smoke, and other, residues with cotton swabs or unscented tissues moistened with
isopropyl alcohol. A commercial glass cleaner may be used, but residues must be removed
with distilled water. Clean with a slow circular motion from center to edge. Dry with a clean,
soft and lint-free cloth or compressed air.
Close the fixture cover and tighten the thumb screw, taking care not to trap any loose wires.

TECHNICAL DATA

PLLEDC64ALN
Power supply:
Consumption:
Led:
Dimensions:
Weight:
AC 110-240V – 50/60Hz
18W
183 (61R – 61G – 61B)
LxWxH mm.255x255x240
kg. 1.45
14