Advertisement

Quick Links

AIR CONDITIONER
OPERATING MANUAL
Duct Type
BEDIENUNGSANLEITUNG
MODE D'EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANIM KİTABI
KEEP THIS MANUAL FOR FUTURE REFERENCE
BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF
CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE
CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA
CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI
ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA
РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ
BU KILAVUZU, DAHA SONRA BAŞVURMAK ÜZERE SAKLAYIN
PART NO. 9374379415-02

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ACY40UI-MI

  • Page 1 AIR CONDITIONER OPERATING MANUAL Duct Type BEDIENUNGSANLEITUNG MODE D’EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ KULLANIM KİTABI KEEP THIS MANUAL FOR FUTURE REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ...
  • Page 2: Table Of Contents

    CONTENTS WEEKLY TIMER ............9 SAFETY PRECAUTIONS ........2 TEMPERATURE SET BACK TIMER ......11 FEATURES AND FUNCTIONS ....... 3 ECONOMY OPERATION ........12 NAME OF PARTS ........... 4 PREPARATORY OPERATION ........ 5 CLEANING AND CARE ......... 12 OPERATION ............6 TROUBLESHOOTING ..........
  • Page 3: Features And Functions

    SAFETY PRECAUTIONS This appliance is not intended for use by persons (including children) with reduced ● CAUTION physical, sensory or mental capabilities, or lack of experience and knowledge, un- less they have been given supervision or instruction concerning use of the appli- ance by a person responsible for their safety.
  • Page 4: Name Of Parts

    NAME OF PARTS Remote controller 1 START/STOP button C Horizontal airfl ow direction and 2 SET TEMP. (temperature) button Swing button 3 MODE button D MAINTENANCE(FILTER RESET) 4 FAN button button 5 ECONOMY button E Operation lamp 6 TIMER MODE (CLOCK AD- F Timer and Clock indicator G Operation mode indicator JUST) button...
  • Page 5: Preparatory Operation

    PREPARATORY OPERATION Set the current day and time Press the DAY button and select the current day. appears around the selected day. Press the TIMER MODE (CLOCK ADJUST) button for 2 seconds or more. The time indicator on the remote controller will fl ash. Press the SET TIME (<...
  • Page 6: Operation

    OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To start/stop operation Press the START/STOP button. Operation lamp Air conditioner ON: Lit brightly Air conditioner OFF: Not lit To set the operation mode Operation mode setting ●...
  • Page 7 OPERATION Room temperature sensor selection This function is locked at the factory. In order to detect the room temperature correctly, consult authorized serv- • ice personnel when using this function. Indoor unit Press the ECONOMY button for more than 2 seconds to select whether the room temperature is detected at the indoor unit or the remote controller.
  • Page 8: Timer Functions

    TIMER FUNCTIONS OFF timer (See page 8.) Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops after the set time has passed. The timer can be set up to 24 hours in advance. ON timer (See page 8.) Use this timer function to start air conditioner operation.
  • Page 9: Weekly Timer

    WEEKLY TIMER Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used. Weekly timer setting Press the TIMER SET button for Press the TIMER MODE button to select the weekly timer. 2 seconds or more. Day of the week setting ●...
  • Page 10 WEEKLY TIMER Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used. WEEKLY timer operation To start To cancel ● ● When the weekly timer is selected, the • Press the TIMER DELETE button to ex.
  • Page 11: Temperature Set Back Timer

    TEMPERATURE SET BACK TIMER Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used. Temperature SET BACK timer setting SET BACK If there is no existing SET BACK tempera- ture setting, “- -” will be displayed for the temperature.
  • Page 12: Economy Operation

    ECONOMY OPERATION Begin air conditioner operation before performing this procedure. To Use the ECONOMY Operation Press the ECONOMY button. The ECONOMY indicator will light. ECONOMY operation begins. To Stop the ECONOMY Operation Press the ECONOMY button again. The ECONOMY indicator will go out. Normal operation begins.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical WARNING breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 14 TROUBLESHOOTING Symptom Problem See Page CHECK ONCE Does not operate at all: Has the circuit breaker been turned off? ● MORE — Has there been a power failure? ● Has a fuse blown out, or a circuit breaker been tripped? ●...
  • Page 15: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Heating Performance* Low Ambient Cooling This air conditioner operates on the heat-pump principle, When the outdoor temperature drops, the outdoor unit’s fans ● absorbing heat from outdoor air and transferring that heat may switch to Low Speed, or one of the fans may stop intermit- indoors.
  • Page 16 OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Mode Operation AUTO (in COOLING model): When AUTO (automatic changeover) operation fi rst selected, the fan will operate at very low speed for about a few ●...
  • Page 17 OPERATING TIPS Instructions relating to inverter ( ) are applicable only to “INVERTER MODEL”. ❖ AUTO Restart In Event of Power Interruption Should the power supply to the air conditioner be interrupted Use of other electrical appliances (electric shaver, etc.) or ●...
  • Page 18: Self-Diagnosis

    SELF-DIAGNOSIS When “Er” in temperature indicator is displayed, inspection of the air conditioning system is necessary. Please consult authorized service personnel. Unit number (usually “00”) Error code ex. Self-diagnosis check En-18...

This manual is also suitable for:

Acg14uia-llAcy25ui-miAcg12uia-llAcy35ui-miAcy50ui-mi

Table of Contents