Johnson Controls XAF Series Installation Manual page 23

Full cased and uncased coils for cooling and heat pumps
Table of Contents

Advertisement

Figure 32: Upflow coil installation
 NOTICE
Dimension Y must be at least 2/3 of dimension Z. See
Figure 32.
Table 7: Duct work dimensions (in.) - XAU coils
Cabinet
width
Coil model
A (in.)
XAUA18A
13 1/2
XAUA24B
13 1/2
XAUB30C
16 1/2
XAUB36D
16 1/2
XAUC42E
20
XAUC48F
20
XAUC60G
20
XAUD60G
23 1/2
XAUD60H
23 1/2
Note: All dimensions are in inches. See Figure 33, Figure 34, and Figure 36.
Installation Manual: XAF, XAH, and XAU Series - Full Cased and Uncased Coils for Cooling and Heat Pumps
Coil shelf
Cabinet
opening
height
width
pre-form
B (in.)
C (in.)
(minimum)
22
9 1/2
24
9 1/2
26
12 1/2
26
12 1/2
28
16
30
16
34
16
34
19 1/2
38
19 1/2
Johnson Controls Ducted Systems
Table 6: Coil projection dimensions - XAU coils
Coil size
Dimension Y (in.)
XAUA18A
3 1/2
XAUA24B
4 1/2
XAUB30C
4 1/2
XAUB36D
5 1/2
XAUC42E
6 1/2
XAUC48F
6 1/2
XAUC60G
9
XAUD60G
9
XAUD60H
9
3.
Install the plenum on the furnace and secure
with screws through the 1/2-in. flange out on the
plenum.
4.
Cut an opening in the front of the supply air
plenum. See Figure 32, Figure 33, Table 6, and Table
7 for coil and coil access dimensions.
5.
Using a folding tool and hand seamer, bend the
sides and top edges of the cut opening forward
from the plenum at a 90° angle. See Figure 33.
Duct
Panel
connector
connector
height
lower
D (in.)
E (in.)
19
19 1/2
21
21 1/2
23
23 1/2
23
23 1/2
25
25 1/2
27
27 1/2
31
31 1/2
31
31 1/2
35
35 1/2
Dimension Z (in.)
5 1/4
6 3/4
6 3/4
8 1/4
9 3/4
9 3/4
13 1/2
13 1/2
13 1/2
Duct
Opening
Opening
width
height
upper
pre-form
pre-form
F (in.)
G (in.)
13
11 1/2
13
11 1/2
16
14 1/2
16
14 1/2
19 1/2
18
19 1/2
18
19 1/2
18
23
21 1/2
23
21 1/2
H (in.)
18
20
22
22
24
26
30
30
34
23