Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.
CAUTIONS Safety cautions Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
Page 6
CAUTIONS Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise qualities these stuffs may be damaged.
Page 7
CAUTIONS Installation Please ask the dealer or specialist to install, never try by the users themselves. After the in be sure of the following conditions. Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard. Air-conditioner can't be installed in the envi- ronment with inflammable gases because the inflammable gases near to air-conditioner may...
Operation Power ON/OFF Used for unit start and stop. SWING Used to set auto fan direction. MODE Used to select AUTO run, COOL,DRY,HEAT and FAN operation. CLOCK Used to set correct time. Used to set correct time. TIMER Used to select TIMER ON, TIMER OFF, TIMER ON/OFF.
Page 9
INTRODUCTION TO SPARE PARTS Operation COOL AUTO SWING FAN SPEED AUTO A U T O SLEEP Clock set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press to set correct time.
INDOOR UNIT Discharge unit (built in) In cooling operation,to discharge the water from inside the room. Outlet Air filter (located in the suction grill) OUTDOOR UNIT A i r i n l e t A i r o u t l e t C o m p r e s s o r ( I n s i d e o f u n i t ) For series 36, 42...
REMOTE CONTROLLER OPERATION Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it from being damaged.
FAN operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL Unit will run in selected mode.
Page 13
AUTO run, COOL,HEAT and DRY operation Recommendations (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display.(Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL...
Page 14
GUIDE TO OPERATION (4) Fan speed selection Press FAN button. For each press, fan speed changes as follows: Unit runs at the speed displayed on LCD. In HEAT mode, warm air will blow out after a short period of time due to cold-draft prevention function. In DRY mode, when room temp.
GUIDE TO OPERATION TIMER operation Set Clock correctly before starting Timer operation(refer to page 6) You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
Page 16
GUIDE TO OPERATION TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2)Press TIMER button to change TIMER mode Every time the button is pressed, display changes as follows: TIMER ON TIMER OFF Select TIMER ON-OFF, "ON"...
Page 17
GUIDE TO OPERATION Adjusting up/down air flow direction Up/down direction can be adjusted by using the SWING button on the remote controller. Each time pressing this button, the mode changes in the following sequence. Change to the AIRFLOW mode. SWING Louver moves in upward downward directions continuously.
Page 18
Press SLEEP button once to make the air conditioner have the previo sleep time (first power-on is "1h"), the sleep symbol will appear. Pre button , you can choose the time in 1~8 hours.
Page 19
Notes: When a power failure suddenly occurs during the air conditioner is working after the pow failure compensation is set, if the air conditioner will not be used for a long time, please cut off power supply to prevent its operation from being resumed after the power is supplied again, or pre the "Switch On/Off"...
MAINTENANCE Appropriate room temperature setting Don't be too low or too high, to make everybody in the room feel comfortable. Cooling 26-28 Don't open the doors and windows. Otherwise reduce the efficiency of the air- conditioner. Don't place any goods around inlet and outlet. These obstacles may lower the efficiency of air-conditioner or stop it.
MAINTENANCE [ Clean air filter ] 3. Dismantle air filter Drag the knob of the grill back lift the filter and take Air filter down. 4. Clean CAUTION! Don't wash with water over 50 discoloring or deforming. Don't dry over fire. Filter maybe burn. (A) Use vacuum suction or (B) wash with water to remove dust.
Page 22
MAINTENANCE [Clean inlet grill] 3. Take of inlet grill Open the inlet grill by an angle of 45 , lift up. 4. Clean CAUTION! Don't wash with water over 50 * ,to prevent decoloring or deforming. Use soft brush, water and neutrul detergent, then swing off the water.
MAINTENANCE [Dismantle and install swing plate ] 3. Install swing plate Lightly rotate swing plate to insert the ridge at both ends of the outlet into the groove and then screw up. NOTE For detailed information consult dealer. Maintenance at the beginning and closing of the applying seaso 1.
TROUBLE SHOOTING The following symptoms are not faults Symptom When stop machine then continue operation. Conditioner doesn't work When press temp setting key and release at once. When power turns on. When humidity too high in the cooling White fog is operation (high content of oil or just in blown out room).