This document describes how to prepare select HP workstations for installation into a fixed rack.

Kit Contents

The following components are included in your fixed rack kit:
Left and right flanges with handles
Left and right rails
Warning label
Rail installation instructions
Warranty
Å
WARNING: Metallic particulates can be especially harmful around electronic equipment. This type of
contamination may enter the data center environment from a variety of sources, including, but not limited
to, raised floor tiles, worn air conditioning parts, heating ducts, rotor brushes in vacuum cleaners, or
printer component wear. Because metallic particulates conduct electricity, they have an increased
potential for creating short circuits in electronic equipment. This problem is exaggerated by the
increasingly dense circuitry of electronic equipment.
Over time, very fine whiskers of pure metal can form on electroplated zinc, cadmium, or tin surfaces. If
these whiskers are disturbed, they may break off and become airborne, possibly causing failures or
operational interruptions. For over 50 years, the electronics industry has been aware of the relatively
rare, but possible, threat posed by metallic particulate contamination. During recent years, a growing
concern has developed in computer rooms where these conductive contaminants are formed on the
bottom of some raised floor tiles.
Although this problem is relatively rare, it may be an issue within your computer room. Since metallic
contamination can cause permanent or intermittent failures on your electronic equipment,
Hewlett-Packard strongly recommends that your site be evaluated for metallic particulate contamination
before installation of electronic equipment.
Fixed Rack Kit Installation
HP Workstations
Four M4 flathead screws
Trim piece
Two adhesive-back plastic glide strips
Rack-mounting template
Hardware bags
1

Advertisement

loading

Summary of Contents for HP xw8200

  • Page 1: Kit Contents

    Fixed Rack Kit Installation This document describes how to prepare select HP workstations for installation into a fixed rack. Kit Contents The following components are included in your fixed rack kit: ■ Left and right flanges with handles ■ Left and right rails ■...
  • Page 2: Supported Racks

    Supported Racks Your HP workstation can be mounted in the following racks: ■ HP Series-E Rack ■ Compaq Rack ■ Many third-party racks, including those with pre-threaded columns NOTE: Each type of rack requires different hardware and tools. Notes in this document identify those differences.
  • Page 3: Prepare The Rack

    ❏ Compaq Rack: Use M6 hardware and follow the rail installation instructions. ❏ HP Series-E rack: Use M5 hardware and follow the rail installation instructions. (M6 screws are required to attach the rails to the front columns of this type of rack.) ❏...
  • Page 4 Remove Top Panel and Foot from Chassis WARNING: Never remove the system access panels without first turning the system off and unplugging Å the power cord from the outlet or Power Protection Device. 1. Turn off the system and disconnect the power cable and all other cables from the back of the system. 2.
  • Page 5 4. Pull the release and slide the foot toward the front of the chassis, then lift it off. 5. Using a screwdriver, push gently through the opening on the top of the chassis to release the top panel. 6. While continuing to push the release button, grasp the top panel and slide it toward the back of the system.
  • Page 6 8. Replace the side access panel: Lower the access panel onto the chassis (aligning the guide rail on the bottom inside edge of the access panel with the bottom edge of the workstation chassis). Close the access panel, ensuring that the guides on the top of the access panel slide into the rails at the top of the chassis.
  • Page 7 Mount the Workstation in the Rack 1. Place the workstation on the rails and slide it into the rack: Holding the workstation with both hands to support its weight, set the workstation on the rails. After the workstation is securely seated on the rails, push the workstation to slide it all the way into the rack.
  • Page 8 This information is intended to prevent damage to the workstation and injury to personnel. 4. Attach cables and power. 313349-002 © 2004 Hewlett-Packard Development Company, L.P. The HP Invent logo is a registered trademark of Hewlett-Packard Development Company, L.P. Mounting...
  • Page 9 固定ラ ッ ク キ ッ ト のイ ン ス ト ール 本書では、 お使いの HP ワ ー ク ス テーシ ョ ン を固定 ラ ッ ク に イ ン ス ト ールす る ための準備の方 法を説明 し ます。 キ ッ ト の内容...
  • Page 10 サポー ト さ れている ラ ッ ク お使いの HP ワー ク ス テーシ ョ ンは、 次の ラ ッ ク に取 り 付け ら れます。 ■ HP シ リ ーズ -E ラ ッ ク ■ Compaq 製 ラ ッ ク ■...
  • Page 11 す。 ❏ HP シ リ ーズ -E ラ ッ ク : M5 ハー ド ウ ェ ア を使用 し て、レールの イ ン ス ト ール手順に従い ます。 ( こ の種類の ラ ッ ク の フ ロ ン ト カ ラ ム に レールを取 り 付け る には、 M6 ネジが必...
  • Page 12 各レールの表面に ス ト リ ッ プ を貼 り 付け ます。 ト ッ プ パネル と 脚を シ ャ ーシから 取 り 外す Å 警告 : シ ス テムのア ク セス パネルは、 必ずシ ス テムの電源を切 り 、 コ ン セ ン ト または電源保護装置 か...
  • Page 13 3. T-15 ト ル ク ス ド ラ イ バ ま たはマ イ ナ ス ド ラ イ バを使っ て、 シ ャ ーシの底のネジ を緩め ま す。 4. リ リ ース を引 き 、 脚を シ ャ ーシの正面に向けて ス ラ イ ド さ せ、 持ち上げて外 し ます。 5.
  • Page 14 7. プ ラ ス チ ッ ク パネルを持ち上げ、 シ ス テ ム シ ャ ーシか ら 取 り 外 し ます。 パネルを後方にス ラ イ ド 注記 : ト ッ プ カバーの取 り 外 し が困難な場合は、 サ イ ド カバーを シ ャ ーシの後側に取 り 付けてい る 2 本 のネジ...
  • Page 15 右側のブ ラ ケ ッ ト を同様に取 り 付け ます。 ワー ク ス テーシ ョ ンのラ ッ クへの取 り 付け 1. ワ ー ク ス テーシ ョ ン を レールに乗せ、 ス ラ イ ド し て ラ ッ ク に押 し 込みます。 重量を支え...
  • Page 16 ます。 こ の情報は、 ワー ク ス テーシ ョ ンへの損傷 と 人体へのケガ を防ぐ ためのものです。 4. ケーブル と 電源を取 り 付け ます。 313349-002 © 2004 Hewlett-Packard Development Company, L.P. The HP Invent logo is a registered trademark of Hewlett-Packard Development Company, L.P. マウン ト 用...