1 Installation

1.1 Dimension Requirements

A
1220 mm
B
636 mm
1
216 mm
C
2
1220 mm
G
3
457 mm
I
4
610 mm
L
5
330 mm
M
N
178 mm
1. min. clearance from the sides of range to
side wall or other combustible material;
2. min. cabinet opening width;
3. upper cabinet to countertop;
8
Installation
4. min. when bottom of wood or metal
5. max. upper cabinet depth.
Y - Grounded outlet
Position within 11
1
48
/
"
16
left rear corner of the range.
25"
X - Gas supply line
1
8
/
"
2
Position within 11
1
48
/
"
16
right rear corner of the range.
18"
24"
13"
7"
cabinet is protected by not less than ¼"
(0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG
sheet steel, 0.015" (0.4 mm) stainless
steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 35" (889 mm)
min. clearance between the top of the
cooking surface and the bottom of an
unprotected wood or metal cabinet.
7
/
8
7
/
8
NOTE: Install with zero
clearance sides and back.
" (300 mm) from the
" (300 mm) from the