Download Print this page

Before Adjustment - Sony SELP1650 Service Manual

Interchangeable lens
Hide thumbs Also See for SELP1650:

Advertisement

Ver. 1.6 2017.03
Note: Perform adjustments after service by referring to this chapter.

4-1. BEFORE ADJUSTMENT

4-1-1. Adjustment Items after Replacing Parts
When replacing main parts and boards, adjust the items indicated by z in the following table.
Note: Do not adjust the items indicated by ×.
Replacement parts
Adjustment Items
Optical Axis Check
z
z
Resolving Power Check/Adjustment
×
z
Performance Check
z
z
(Image Shaking/Jumping)
Lens Device (S)
×
z
Steady Hall (S)
×
×
Magnet Resistor (S)
×
×
Flange Back (S)
×
z
F Number (S)
×
×
Gyro Sensor (S)
×
×
Rom Check
z
z
Adjustment execute Check
z
z
Lens Sleep
z
z
SELP1650 (E 3.5-5.6/PZ 16-50 OSS) (E PZ 16-50mm F3.5-5.6 OSS)
z
z
z
z
z
z
z
×
×
z
z
z
z
z
z
z
z
z
z
z
z
×
×
×
×
×
z
z
×
×
×
×
×
×
z
×
×
×
×
×
×
z
×
z
z
z
z
z
z
×
×
×
×
×
z
z
×
×
×
×
×
×
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
4. ADJUSTMENTS
4-1-2. Adjustment/Check Order Flowchart
After Replacing
Parts
NG
Check the optical axis
Section 4-2
OK
Check the
NG
resolving power
Section 4-3
OK
z
z
z
Check the
NG
Performance
×
(Image Shaking/Jumping)
section 4-5
×
×
OK
z
×
Lens Adjustment Program
E-Mount Lens Adjustment
Lens Device (S)
z
Section 4-6
z
z
Steady Hall (S)
z
Magnet Resistor (S)
Flange Back (S)
F Number (S)
Gyro Sensor (S)
Rom Check
Adjustment execute Check
Lens Sleep
4-1
Replace the
NG
Replace the
Check the optical axis
1 Group Block
2 Group Block
Section 4-2
Assy
OK
Adjust the
Check the
NG
Replace the
resolving power
resolving power
1 Group Block
Section 4-4
Section 4-3
OK
Lens Adjustment Program
E-Mount Lens Adjustment
Section 4-6
Check the
NG
Replace the
Performance
Flange Back (S)
1 Group Block
(Image Shaking/Jumping)
section 4-5
OK
END
NG
Check the optical axis
Section 4-2
Assy
OK
Check the
NG
resolving power
Assy
Section 4-3
OK
Check the
NG
Performance
(Image Shaking/Jumping)
Assy
section 4-5
OK
Replace the Service
Exclusive Optics Block

Advertisement

loading