Never locate heater where it may fall into a bathtub or other water container. The Chromalox DRA is shipped fully assembled. The handle is assembled in the lower position (dotted line Fig. 1). To position handle in the upright position, remove bolts securing the handle to...
Page 3
Non Locking .750”-1.250” Non Locking The above plugs are designed to be used with specific ranges of cable diameters. If not used with Chromalox Cable Kits, check cable man- ufacturers cable diameter to be sure plug fits selected cable. WIRING...
*Includes 90 degree fitting and 25 foot of cord, reducers and locknut 2. Strip off outer jacket of cord and insulation from lead wires. The tabulation below provides the strip dimensions for the var- ious Chromalox portable heaters. See the nameplate on the heater for the Model number. Model No.
Diag. 1 – FACTORY WIRED 3 PHASE Cord by others. Type "SO" or equal sized to meet nameplate requirements Thermostat Cutout Diag. 2 – FACTORY WIRED 3 PHASE Cord by others. Type "SO" or equal sized to meet nameplate requirements To T3 Contactor To T3...
The ends of the elements are color coded, the lower wattage are color coded yellow and the higher wattage are color coded blue. a. Lower wattage elements, discharge end, yellow coded b. Higher wattage elements, fan end, blue coded Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. MAINTENANCE Replace or repair damaged cords or plugs immediately.