Download Print this page

HP ProCurve 4148 Specifications page 6

Procurve switch 4100gl series

Advertisement

ProCurve Switch 4100gl Series
Switch fabric speed
Routing table size
Environment
Operating temperature
Operating relative humidity
Non-operating/Storage
temperature
Non-operating/Storage relative
humidity
Altitude
Electrical characteristics
Maximum heat dissipation
Voltage
Current
Power consumption
Frequency
Safety
Emissions
Immunity
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
Flicker
Management
18.3 Gbps
8000 entries
32ºF to 131ºF (0ºC to 55ºC)
15% to 95% @ 104ºF (40ºC),
non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 95% @ 149ºF (65ºC),
non-condensing
up to 15091 ft. (4.6 km)
2152 BTU/hr (2270.36 kJ/hr)
100-127 / 200-240 VAC
8.2 / 3.8 A
630 W
50 / 60 Hz
cUL (CSA 950); EN 60950/IEC
60950; NOM-019-SCFI-1994; UL
1950 3rd edition
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power
line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60
Hz
IEC 61000-4-11; >95% reduction,
0.5 period, 30% reduction, 25
periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
36.6 Gbps
8000 entries
32ºF to 131ºF (0ºC to 55ºC)
15% to 95% @ 104ºF (40ºC),
non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 95% @ 149ºF (65ºC),
non-condensing
up to 15091 ft. (4.6 km)
2152 BTU/hr (2270.36 kJ/hr)
100-127 / 200-240 VAC
8.2 / 3.8 A
630 W
50 / 60 Hz
cUL (CSA 950); EN 60950/IEC
60950; NOM-019-SCFI-1994; UL
1950 3rd edition
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power
line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60
Hz
IEC 61000-4-11; >95% reduction,
0.5 period, 30% reduction, 25
periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
18.3 Gbps
8000 entries
32ºF to 131ºF (0ºC to 55ºC)
15% to 95% @ 104ºF (40ºC),
non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 95% @ 149ºF (65ºC),
non-condensing
up to 15091 ft. (4.6 km)
2152 BTU/hr (2270.36 kJ/hr)
100-127 / 200-240 VAC
8.2 / 3.8 A
630 W
50 / 60 Hz
cUL (CSA 950); EN 60950/IEC
60950; NOM-019-SCFI-1994; UL
1950 3rd edition
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power
line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60
Hz
IEC 61000-4-11; >95% reduction,
0.5 period, 30% reduction, 25
periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
6

Advertisement