RESOLUTION CHECK
MUTE
INFORMATION
MODEL
SERIAL NO
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
Controlling the Monitor with a computer (RS-232C)
Command
Direction
Parameter
PXCK
R
MUTE
WR
0-1
INF1
R
SRNO
R
DSTA
R
ERRT
R
STCA
W
0
R
Reply
- Returns current resolution in the form of hhh, vvv.
0-1 0: OFF, 1: ON
Value
Value
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting