Features
1. THERMOSTAT DIAL: For controlling the
temperature inside the freezer. Turns the motor on
as soon as the temperature rises above the
desired level.
2. REFRIGERATED SHELVES: 3 full width
refrigerated shelves.
3. MAGNETIC GASKET: Tight fitting door seal keeps
all the cooling power locked inside. No hooks or
latches.
8. DOOR BINS (4)
5. DRIP TRAY
1
2
5

DOOR REVERSAL INSTRUCTIONS

CAUTION: To avoid personal injury to yourself
and/or property, we recommend someone assist
you during the door reversal process.
1. To access the lower hinge assembly, tilt back the
freezer cabinet or lay the freezer on its back. (Fig.
C)
2. Remove both leveling legs located at the front of
the cabinet.
3. Remove the screws holding the lower hinge
assembly to the cabinet.
4. Remove the main door assembly from the freezer
cabinet. (lift door slightly and pull downward)
5. Using a flat heat screwdriver, remove (unscrew)
the main door top hinge pin. (Fig. D)
6. Re-install the main door top hinge pin on the
opposite side of the cabinet.
7a. Remove the door plug and door bushing located
on the top of the main door assembly.
7b. Interchange their positions. (eg. door plug right
side, door bushing left side.)
8. Re-install main door assembly on cabinet.
9. Remove door bushing (bottom door) and install on
opposite side.
10. Re-install the lower hinge assembly on the
opposite side.
11. Make sure the door assembly is properly aligned
on the cabinet before tightening lower hinge
screws.
3
12. Re-install both leveling legs.
The process is now complete.
Fig. C