Monogram ZIRP360NHLH Installation Instructions Manual page 15

36” built-in all-refrigerators and all-freezers
Table of Contents

Advertisement

Installation Instructions - Standard Installation
STEP 4 INSTALL ANTI-TIP BRACKET (cont.)
Install Wall Toggles:
The wall toggles and bolts can be ordered as Service
Kit #WR49X10193. Wall toggles are installed in the
drywall and metal studs for stability. Install the wall tog-
gles as follows:
• Drill 1/2" holes at the wall markings made in the holes
at the ends of the wall bracket.
• Hold the metal channel flat against the plastic straps
and slide the channel through the hole.
Plastic Straps
• Gently pull back at the ends of the plastic straps to
make the channel rest flush behind the wall.
• Hold the ends of the straps in one hand and slide the
plastic cap along the straps until the flange of the cap
is flush with the wall.
Cap
• Place your thumb between the plastic straps and
bend up and down to snap the straps off at the wall.
Metal Channel
Install Screws and Bolts:
• Have someone hold the wall bracket centered in place
with each of the holes aligned with the correct opening
in the bracket and level with the horizontal line.
• Insert the lag screws through the bracket and into the
stud. Tighten with a wrench.
Lag Screw
Anti-Tip Wall Bracket
Insert the bolts into the toggle by hand until snug.
Tighten with a wrench.
Bolt
Anti-Tip Wall Bracket
15
Wood Stud
Drywall or
Steel Stud
Wall Toggle