C3.
CHECK MICROWAVE ASSEMBLY
Exhaust Adaptor (absent
on models shipped for
recirculation exhaust)
•
Place the microwave in its upright position, with the
top of the unit facing up.
•
The microwave oven may be shipped assembled for
top exhaust (adaptor installed) or for recirculation
exhaust (adaptor absent).
•
If the microwave was shipped for recirculation
exhaust, skip to C5. If shipped for top exhaust,
proceed with C4.
C4.
ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION
Remove tape securing damper.
1
2
Raise damper flap.
Blower Plate
4
Remove the screw that holds the blower plate
to the microwave. Remove and save the screw
holding the blower motor to the microwave.
NOTE: The blower plate will be reinstalled in a
later step. The damper is not needed for recirculating
models. Save any unused parts for possible future use.
Installation Instructions
Back of
Microwave
Slip the damper
3
out of the track
on the blower
frame by pressing
and twisting
both ends.
Back of Microwave
Blower Plate
Back of
Microwave
Blower Motor
Screw
20
5
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust the
blower unit.
6
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the microwave.
BEFORE: Fan Blade
Openings Facing Up
Roll
AFTER: Fan Blade
Openings Facing
Forward
NOTE: Make sure wires remain routed in the
grooves of the motor frame.