Detaching And Refitting The Pf Main Pwb - Kyocera AK-730 Service Manual

Hide thumbs Also See for AK-730:
Table of Contents

Advertisement

(2) Detaching and refitting the PF main PWB

Procedure
1. Remove the DF rear cover.
2. Remove all connectors from the DF
main PWB.
3. Remove four screws.
4. Remove the DF main PWB.
5. Check or replace the DF main PWB
and refit all the removed parts.
CAUTION:when replacing the DF main
PWB, remove the EEPROM (U4) from
the DF main PWB that has been
removed and then reattach it to the new
DF main PWB.
All manuals and user guides at all-guides.com
1-5-4
Screw
Screw
YC15
YC16
YC3
YC19
DF main PWB
Figure 1-5-4
3NC/3NB/3NK
DF main PWB
Screw
Screw
YC11
YC7
YC8
YC5