Power failure
During nanoe™ X individual operation, if power failure occurs, after power resumes, nanoe™ X individual
o
operation resumes immediately.
During combination operation, if power failure occurs, after power resumes, combination operation resume
o
immediately.
nanoe™ X check mode
To enable nanoe™ X check mode, during nanoe™ X operation ON:
o
During nanoe™ X check mode, H67 is judged when disconnection detected. Timer LED blinks.
o
nanoe™ X Abnormal Detection
Disconnection Abnormality
o
Abnormal detection condition
Start from 1 sec after nanoe™ X power ON, 6 secs has passed and in this 6 secs period, abnormal
signal is detected continuously for 5.9 secs.
Action after abnormal detection condition fulfilled
Disconnection counters +1, nanoe™ X power OFF for 5 minutes and then restart. However,
according to action mode and disconnection counter, below will be implemented:
During nanoe™ X Check Mode: Disconnection abnormality will judged when disconnection
o
counter ≥ 1. Abnormal code: H67 will memorized in EEPROM, Timer LED blinking and nanoe™
X LED Off.
Other Than Above: Disconnection abnormality will judged when disconnection counter ≥ 3.
o
Abnormal code: H67 will memorized in EEPROM and nanoe™ X LED OFF, Timer LED not
blinking.
Disconnection counters clear condition >
Disconnection counter will be cleared when operation stop. (Not nanoe™ X Check Mode)
nanoe™ X Discharge Abnormality
o
Abnormal detection condition
After 30 minutes nanoe™ X power ON, abnormal signal is being detected continuously for 5s.
Action after abnormal detection condition fulfilled
Abnormal discharge counter +1, nanoe™ X power OFF for 30 minutes and then restart. When
abnormal discharge counter ≥ 12, abnormal code: H67 in analyze area (Area where abnormal code
not displayed) will be memorized.
Abnormal discharge counters clear condition
Discharge counter will be cleared when operation become normal for 50 mins above or when
operations stop.
Normal display mode
Press
SW (t ≥ 0 secs)
When
SW pressed continuously for t ≥ 5 secs to enter service zone
and press
SW'sto choose function 57
Transmit
"NANOE™ X CHECK" code