Nokia RM-509 Service Manual page 35

Mobile phones
Hide thumbs Also See for RM-509:
Table of Contents

Advertisement

RM-509; RM-510; RM-511
Service Devices and Service Concepts
Issue 2
CU-4
CU-4 is a general service tool used with a module jig and/or a flash
adapter. It requires an external 12 V power supply.
The unit has the following features:
• software controlled via USB
• EM calibration function
• Forwards FBUS/Flashbus traffic to/from terminal
• Forwards USB traffic to/from terminal
• software controlled BSI values
• regulated VBATT voltage
• 2 x USB2.0 connector (Hub)
• FBUS and USB connections supported
When using CU-4, note the special order of connecting cables and
other service equipment:
Instructions
1 Connect a service tool (jig, flash adapter) to CU-4.
2 Connect CU-4 to your PC with a USB cable.
3 Connect supply voltage (12 V)
4 Connect an FBUS cable (if necessary).
5 Start Phoenix service software.
Note:
Phoenix enables CU-4 regulators via USB when it is
started.
Reconnecting the power supply requires a Phoenix restart.
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
Control unit
Page 2 –9

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

3711 fold3710 foldRm-510Rm-511

Table of Contents