Diagnosis
Abnormality /
display
Protection control
Outdoor cooling high
F95
pressure protection
Power transistor
F96
module overheating
protection
Compressor
F97
overheating
protection
Total running current
F98
protection
Outdoor direct
F99
current (DC) peak
detection
Abnormality
Protection
Judgment
Operation
4 times happen
within 20 minutes
4 times happen
within 30 minutes
3 times happen
within 30 minutes
3 times happen
within 20 minutes
Continuous
happen for 7 times
Problem
Cooling high pressure
protection
Power transistor module
overheat
Compressor overheat
Total current protection
Power transistor module
current protection
59
Check location
 Check refrigeration system
 Outdoor air circuit
 PCB faulty
 Outdoor air circuit (fan motor)
 Insufficient refrigerant
 Check refrigeration system
 Power source or compressor
lock
 Power transistor module faulty
or compressor lock