11.2 Outdoor Unit

11.2.1
Select the Best Location
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
Example: For E12***
If the unit is installed at 10 m distance, the quantity of
additional refrigerant should be 50 g .... (10-7.5) m x
20 g/m = 50 g.
11.2.2
Install the Outdoor Unit
After selecting the best location, start installation
according to Indoor/Outdoor Unit Installation
Diagram.
1
Fix the unit on concrete or rigid frame firmly
and horizontally by bolt nut (ø10 mm).
2
When installing at roof, please consider strong
wind and earthquake.
Please fasten the installation stand firmly with
bolt or nails.
11.2.1.1
Indoor/Outdoor Installation
Diagram
Model
A
E12***
540 mm
E18***
613 mm
35
B
C
160 mm
18.5 mm
330 mm
131 mm
16 mm
360.5 mm