Siemens WT45HVG3 User Manual And Installation Instructions page 39

Table of Contents

Advertisement

Fault
The programme does
not start.
The length of the pro-
gramme changes dur-
ing the drying cycle.
Pumping noise.
Buzzing noise.
The drying time is too
long.
Water is leaking from
the appliance.
Cause and troubleshooting
Childproof lock is activated.
→ "Deactivating the childproof lock", Page 31
You have not pressed  Start Nachlegen .
Press Start Nachlegen .
No programme set.
→ "Setting a programme", Page 25.
1.
→ "Starting the programme", Page 26.
2.
The programme operation is optimised electronically.
This may change the programme duration.
Not a fault – no action required.
Condensation pump active.
Not a fault – normal operating noise.
Compressor ventilation active.
Not a fault – normal operating noise.
The base unit's filter is soiled.
→ "Cleaning the filter system on the base unit",
Page 28
Fluff filter is soiled.
→ "Cleaning the fluff filter", Page 27
The ambient temperature is greater than 30 °C.
Ensure that the ambient temperature is lower than
30 °C.
The ambient temperature is lower than 15 °C.
Ensure that the ambient temperature is above 15
°C.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
Appliance air inlet is blocked.
Ensure that the air inlet on the appliance is kept
clear.
Heat exchanger is soiled.
→ "Opening the base unit", Page 33.
1.
Clean the heat exchanger.
2.
→ "Cleaning the base unit", Page 34
→ "Closing the base unit", Page 35.
3.
Appliance is not correctly aligned.
→ "Aligning the appliance", Page 14
The seal for the heat exchanger cover is dirty.
Troubleshooting en
39

Advertisement

Table of Contents
loading

Table of Contents