Thermistors - GE Zoneline Generation III 2800 Series Technical Service Manual

Table of Contents

Advertisement

Thermistors

The 2800 series electric heat models use two
thermistors:
Room Air Temperature
Indoor Coil Temperature
The 3800 series (heat pump models) uses 4
thermistors:
Room Air Temperature
Indoor Coil Temperature
Outdoor Coil Temperature
Outdoor Air Temperature
THERMISTOR
The thermistors can be checked to determine if
they are good. Below is a chart showing thermistor
resistance values at various temperatures.
Thermistor Chart
Room
Indoor
°F
Air
Coil
10
63260
94900
30
34620
51940
32
32890
49330
50
19970
29960
70
11950
17930
90
7320
10970
Thermistor Location
Room Air Thermistor (2800 & 3800 Model Series)
The indoor air thermistor is located in front of the
indoor coil where it detects the temperature of
the room air being returned to the unit. It is held in
position away from the coil by a plastic fastener
that is pushed between the coil plate fi ns. The room
air thermistor is connected to the control board at
CN1 (yellow wires).
Indoor Coil Thermistor (2800 & 3800 Model Series)
The indoor coil thermistor is mounted in a copper
tube that is brazed to an end turn at the right side
of the indoor coil.
All manuals and user guides at all-guides.com
LEADS
3800 Series
Outdoor Coil
Outdoor Air
28030
15340
14570
8850
5300
3280
The indoor coil thermistor is connected to the control
board at CN1 (orange wires).
Room Air Thermistor
Outdoor Air Thermistor (3800 Model Series)
The outdoor air thermistor is located on a metal
bracket just behind the compressor. It detects the
temperature of the outdoor air being drawn into the
unit. The outdoor air thermistor is connected to the
control board at CN1 (blue wires).
Outdoor Coil Thermistor (3800 Model Series)
The outdoor coil thermistor is located in a copper
tube that is brazed to an end turn at the right side
of the outdoor coil. The outdoor coil thermistor is
connected to the control board at CN1 (black wires).
Outdoor Air Thermistor
– 42 –
Indoor Coil Thermistor
Outdoor Coil Thermistor