Mitsubishi Electric MXZ-2A20NA-1 Service Manual page 26

Outdoor unit inverter-controlled multi system type
Hide thumbs Also See for MXZ-2A20NA-1:
Table of Contents

Advertisement

MXZ-3A30NA MXZ-3A30NA -
Function
Condition
"A" Cooling Steady State
at rated compressor Speed
"B-2" Cooling Steady State
at rated compressor Speed
"B-1" Cooling Steady State
Cooling
at minimum compressor Speed
Low ambient Cooling Steady State
at minimum compressor Speed
Intermediate Cooling Steady State
At Intermediate compressor Speedw
Standard Rating-Heating
at rated compressor Speed
Low temperature Heating
at rated compressor Speed
Max. temperature Heating
at minimum compressor Speed
Heating
High temperature Heating
at minimum compressor Speed
Frost Accumulation
at rated compressor Speed
Frost Accumulation
at Intermediate compressor Speedw
w At Intermediate compressor Speed
=("Cooling rated compressor speed" - "minimum compressor speed") / 3 + "minimum compressor speed".
MXZ-2A20NA MXZ-2A20NA -
The standard specifications apply only to the operation of the air conditioner under normal conditions.
Since operating conditions vary according to the areas where these units are installed, the following information has been pro-
vided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198 ~ 253V 60Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature :
(2) Indoor outlet air wet-bulb temperature :
(3) Outdoor intake air dry-bulb temperature :
(4) Total input:
(5) Indoor intake air dry-bulb temperature :
(6) Outdoor intake air wet-bulb temperature :
(7) Total input :
Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the
indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.
How to measure the indoor air wet-bulb/dry-bulb temperature difference
1.
Attach at least 2 sets of wet-and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet-and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2.
Attach at least 2 sets of wet-and dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3.
Check that the air filter is cleaned.
4.
Open windows and doors of room.
5.
Press the EMERGENCY OPERATION switch once(twice) to start the EMERGENCY COOL(HEAT) MODE.
6.
Compressor starts running at 33Hz (COOL) or 45Hz (HEAT). The frequency at each operation mode is fixed.
7.
When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
8.
10 minutes later, measure temperature again and check that the temperature does not change.
INDOOR UNIT
1
Intake air
temperature
MXZ-3A30NA MXZ-3A30NA -
1
Wet-and dry-bulb
thermometers
Indoor
DB (˚F)
WB (˚F)
80
67
80
67
80
67
80
67
80
67
70
60
70
60
70
60
70
60
70
60
70
60
1
}
°FWB
°FWB
Cooling
°FDB
W
}
°FDB
Heating
°FWB
W
OUTDOOR UNIT
26
Outdoor
DB (˚F)
WB (˚F)
95
(75)
82
(65)
82
(65)
67
(53.5)
87
(69)
47
43
17
15
62
56.5
47
43
35
33
35
33
Wet-and dry-bulb
thermometers

Advertisement

Table of Contents