SELF-DIAGNOSIS FUNCTION
22
Error code
21
DC Peak (IPM Fault)
22
Max. CT (CT2)
23
DC Link low volt.
26
DC Comp position error
27
PFC Fault error
29
Comp over current
32
D-Pipe high (Inv.)
35
Low pressure error
38
Refrigerant leakage detect error
40
CT sensor error (open/short)
41
Inv. D-Pipe sensor error (open/short)
43
Pressure sensor (open/short)
44
Outdoor air sensor error (open/short)
45
Cond. Middle pipe sensor error
51
Capacity over
53
Communication error (indoor - outdoor)
60
EEPROM error (outdoor)
61
Cond. Middle pipe high
62
Heatsink error
65
Heatsink sensor error (open/short)
67
BLDC motor fan lock (outdoor)
If abnormal voltage is supplied, the protection circuits will turn off the product in order to prevent
the component damage. The product will automatically restart after 3 minutes.
Description
LED (Red)
LED (Red)
LED 1 (Red) LED 2 (Green)
2times ◑
1times ◑
2times ◑
2times ◑
2times ◑
3times ◑
2times ◑
6times ◑
2times ◑
7times ◑
2times ◑
9times ◑
3times ◑
2times ◑
3times ◑
5times ◑
3times ◑
8times ◑
4times ◑
0
4times ◑
1times ◑
4times ◑
3times ◑
4times ◑
4times ◑
4times ◑
5times ◑
5times ◑
1times ◑
5times ◑
3times ◑
6times ◑
0
6times ◑
1times ◑
6times ◑
2times ◑
6times ◑
5times ◑
6times ◑
7times ◑
Indoor
status
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Restart after
3 minutes
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF