Die And Connector Selection - Greenlee GATOR EK425 Instruction Manual

Battery-powered crimping tool
Table of Contents

Advertisement

CJ22 Jaw and KA22/KC22-type Die Selection
Note:  This tool will provide a cUL and UL classified crimp ONLY when used with the CJ22 jaws and KA22- or KC22-type dies.
Crimps made on copper cable with Greenlee KC22-type dies and the copper connectors listed here are
cUL and UL classified.
Crimps made on copper or aluminum cable with Greenlee KA22-type dies and the dual-rated aluminum connectors
listed here are cUL and UL classified.
Refer to "Connector Selection" for brand names and model numbers of appropriate lugs as well as crimping instructions.
Dies for Copper Connectors
Catalog
UPC
Number
Number
KC22-8
03079
KC22-6
03080
KC22-4
03081
KC22-2
03082
KC22-1
03083
KC22-1/0
03084
KC22-2/0
03085
KC22-3/0
03086
KC22-4/0
03087
KC22-250
03088
KC22-300
03089
KC22-350
03090
KC22-400
03091
KC22-500
03092
KC22-600B
08094
Connector Selection
CJ22 Crimping Jaw Range: Copper — 8 AWG to 600 kcmil†; Dual-rated Aluminum — 8 AWG to 350 kcmil
When used with KC22-type dies, this tool is cUL and UL classified for use with the following connector brands:
Connector Barrel Anderson Blackburn
Type
Type
Copper
Short
VHSS
Splice
Long
VHS
Short
VHCS
Copper
Lugs
Long
VHCL
When used with KA22-type dies, this tool is cUL and UL classified for use with the following connector brands:
Connector Barrel Anderson Blackburn
Type
Type
Dual-rated
Aluminum
VACS
Splice
Dual-rated
Aluminum
VACL
Lugs
* Use the number of crimps listed in the last column instead of the number provided with the connector:
A — 8 to 1/0 AWG: 1 crimp
95R7
** 6 AWG to 350 kcmil
† 500 kcmil maximum with Penn-Union connectors
Greenlee / A Textron Company
Cable
Color
Size
Code
8 AWG
Red
6 AWG
Blue
4 AWG
Gray
2 AWG
Brown
1 AWG
Green
1/0 AWG
Pink
2/0 AWG
Black
3/0 AWG
Orange
4/0 AWG
Purple
250 AWG
Yellow
300 AWG
White
350 AWG
Red
400 AWG
Blue
500 kcmil
Brown
600 kcmil
Green
FCI Burndy
®
CSP
YS-L
CU
YS
CTL-2/CTL
YA-2LN/YA-L/YA-2L
YA/YA-L-TC/YA-L-2TC
CTL-L/LCN
YA-2N
FCI Burndy
®
ASP
YS-A
YA-A
ATL
YA-ATN
2/0 AWG to 600 kcmil: 2 crimps
EK425 Battery-powered Crimping Tool
Dies for Dual-rated Aluminum Connectors
Catalog
Number
KA22-8
KA22-6
KA22-4
KA22-2
KA22-1
KA22-1/0
KA22-2/0
KA22-3/0
KA22-4/0
KA22-250
KA22-300
KA22-350
Ilsco
Panduit
CT
SCSS/SCS
CTL
SCL/SCH
CRA/CRB
LCAS/LCA
CRA-L/CRB-L
LCB/LCC 54930BE–54918BE
CRA-2L/CRB-2L
Ilsco
Panduit
AS
ACL/ACN
LAA/LAB
2ACL/2ACN
B — 8 to 2 AWG: 2 crimps
1 to 3/0 AWG: 3 crimps
4/0 AWG to 350 kcmil: 4 crimps
8
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
UPC
Cable
Number
Size
06744
8 AWG
06745
6 AWG
06746
4 AWG
06747
2 AWG
06749
1 AWG
06750
1/0 AWG
06751
2/0 AWG
06752
3/0 AWG
06753
4/0 AWG
06754
250 AWG
06755
300 AWG
06756
350 AWG
T&B
54504–54518
54804–54818
54104–54118
LCD
54204–54218
54850BE–54876BE
T&B
SA
60501–60565
**
60101–60166
**
60230–60267
Penn-
No. of
Union† Crimps*
BCU
BBCU
BLU
A
BBLU
Penn-
No. of
Union
Crimps*
PIK
B
BLUA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents