Panasonic SA-AK750PL Service Manual page 22

Table of Contents

Advertisement

SA-AK750PL
The error code is automatically display after entering into self-diagnostic mode.
9.4.1.
Error Code Table for Deck Mechanism
Error Code Diagnosis Contents Description of error
H01
Mode SW, plunger
and capstan motor
abnormal
H02
Rec INH SW
abnormal
H03
HALF SW abnormal
F01
Reel pulse abnormal
9.4.2.
Error Code Table For CD Changer Block
Error Code Diagnosis Contents Description of error
F15
RESET SW
abnormal
F26
Transmission error
between CD Servo
LSI IC and
microprocessor IC
IHMS
Cam gear
abnormality
ICSL
Cam gear/gear units
abnormal
ISTK
Drive rack/gear
assembly abnormal
IPLY
Drive rack/gear
assembly abnormal
ITOP
UD assembly
IUDS
UD assembly
Normal
operation
during
mecha transition, MODE
SW
abnormal
is
memorized. The content of
abnormality
can
be
confirmed in the abnormal
detection mode explained
in the later section.
The content of abnormality
can be confirmed in the
abnormal detection mode
explained
in
the
later
section.
REST
SW:
ON is
not
detected
within
the
specified time.
When set to CD mode, the
sense signal does not turn
"Low", a fail safe time after
system
command
transmission is sent.
Cam gear does not rotate
to "HOME" position.
Cam gear does not rotate
to "PLAY" driving position
and hence does not drive
playing tray to "STOCK"
position.
The tray drive rack does not
move to "STOCK" position.
(Tray does not move to
"STOCK" position)
The tray drive rack does not
move to "PLAY" position.
(Tray does not move to
"PLAY" position)
UD Rack does not move to
front direction. This lead to
UD base not raise to top
position.
After TOP SW is detected,
UD rack does not move into
tray 1 position.
Automatic FL Display
Automatic FL Display
22
Remarks
For deck mechanism unit.
Press [
] on main unit for
next error.
For deck mechanism unit.
Press [
] on main unit for
next error.
For deck mechanism unit.
Press [
] on main unit for
next error.
For deck mechanism unit.
Press [
] on main unit for
next error.
Remarks
For CD unit (For Traverse).
Press [
] on main unit for
next error.
For CD unit (For Traverse).
Press [
] on main unit for
next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sb-ak750Sb-wak750

Table of Contents