A
D
E
B
L
Clearance above grade, veranda, porch, deck, or
A
balcony
B Clearance to window or door that may be opened
C Clearance to permanently closed window
Vertical clearance to ventilated soffit located above
the vent terminator within a horizontal distance
D
of 2 feet (61cm) from the center line of the
terminator
E Clearance to unventilated soffit
F Clearance to outside corner
G Clearance to inside corner
Clearance to each side of center line extended
H
above meter/regulator assembly
I
Clearance to service regulator vent outlet
Clearance to non-mechanical air supply inlet to
J
building or the combustion air inlet to any other
application
K Clearance to mechanical air supply inlet
Clearance above paved sidewalk or paved driveway
L
located on public property
M Clearance under veranda, porch deck, or balcony
*For clearances not specified in ANSI Z2231 / NFPA 54 or CAN/CSA-B1491, please use clearances in accordance
with local installation codes and the requirements of the gas supplier
-Vent termination clearances-
INSIDE CORNER DETAIL
G
V
B
C
V
V
B
V
F
B
B
17
Page
V
Vent terminal
X
Air supply inlet
Area where is not permitted
H
B
V
X
V
J
A
Gas meter / regulator
Canada
Direct-vent and other
Direct-
than Direct-vent
vent
1 foot
1 foot
3 feet
1 foot
*
*
*
*
*
*
*
*
*
*
3 feet
*
3 feet
*
3 feet
1 foot
6 feet
3 feet
7 feet
*
1 foot
*
Installation Manual
Installation
M
X
I
V
K
USA
Other than
Direct-vent
1 foot
4 feet from below or
side opening 1 foot
from above opening
*
*
*
*
*
*
*
4 feet from below or
side opening 1 foot
from above opening
3 feet
7 feet
*

Advertisement