Fetco CBS-2152XTS-2G Users Manual And Operator Instructions page 8

Hot beverage brewers
Table of Contents

Advertisement

GENERAL
Programming Items
Tank Temp.
"OFF" allows
Brew at Temp.
brewing at any
temperature.
• Temperature
Units of Meas.
• Volume
ECO Mode
Logo Timeout
Brew B. Sensor
Use Flowjet
Normal for most water
LLC Sensitivity*
"HIGH" for R.O.
Most water has sufficent mineral content for proper brewer refill cycling. If refill is erratic, inspect all wiring and if
"ERROR CODE 107" displays, or if water is tested to be very pure (<100 TDS or 5.5 grain), :set LLC to "HIGH".
BREW AT TEMPERATURE DEFINITONS
--------------------------------------------------------------------------------
ON
BREW AT TEMP: "
"
(DEFAULT: FACTORY PROGRAMMED INTO BREWER)
"BREW START" Batch Section Buttons will not be accessible
until tank temperature is at set point.
The "BREW START" screens with the Batch Section Buttons
become accessible when hot water tank is at the selected
temperature. A screen (example to the right) will display showing
"BREW AT TEMP" is selected.
--------------------------------------------------------------------------------
BREW AT TEMP: AUTO
"BREW START" will pause if the hot water tank is not at the
selected temperature—and automatically start when it is at the
set temperature.
If the temperature is too low, the brewer will wait until the proper
temperature is reached. A screen (example to the right) will
display showing a thermometer icon and the tank temperature .
IMPORTANT: ALWAYS have dispenser(s) under the brewer
when in the BREW AT TEMP mode
----------------------------------------------------------------------------------------------------------
OFF
BREW AT TEMP:
Allows brewing at any temperature above 170°F/77°C.
May NOT apply for two sided brewer if one side is in brew cycle
If Selected: Turns heaters off after 1 hour of inactivity.
The hot water tank temperature will slowly decline to no lower than 60°C/170°F
A screen (example to the right) will display showing "ECO Mode" is activated.
To return from ECO-Mode
Tap the screen, ECO Mode turns off, and the brewer will heat to set temperature.
It takes approximately 7-15 minutes to return from 60°C/170°F to factory default 93°C/200°F
All FETCO commercial hot beverage equipment have well insulated hot water tanks and
have engineered mechanical features to limit energy consumption
Effective construction and insulation increases equipment life and lowers building HVAC costs.
FETCO hot beverage equipment have the best energy savings of all major suppliers.
Factory set Default
200°F
"ON"
°C or °F
Gallons [Liters]
Energy Saving
OFF
Mode
0:30 mm:ss
NORMAL
(SEE WARNINGS)
NO
NORMAL
USER SELECTABLE
USER SELECTABLE
ECO MODE-Energy saving mode DEFINITONS
Programming Range (display)
|______________[]___|
170
|________[]_______|
OFF
|___[]____________|
°F
|___[]____________|
Gallons
ECO Mode
_______________[]_____
ON
0:30 mm:ss
|__[]___________|
0:15
|__[]____________|
NORMAL
____[]_______________
NO
NORMAL
____[]______________
NORMAL
X
T
S
X
T
S
E
X
T
R
A
C
T
O
R
E
X
T
R
A
C
T
O
R
T
O
U
C
H
S
C
R
E
E
N
T
O
U
C
H
S
C
R
E
E
N
CBS 2100
Ready
Tank Temp
Heating
92
°C
Filling
Regular 1
|■| 3:00
INFO
6:00
Regular 2
|■| 3:00
6:00
Decaf 1
92°C
|■| 3:00
6:00
Decaf 2
|■| 3:00
STOP
6:00
(Not recommended)
.
8
200 °F
Chart to correct for
high altitude below
207
ON
SEE NOTE BELOW!
ON AUTO
°F
°C
Gallons
Liters
If Selected: Lowers hot
water tank temperature to
OFF
5:00
Factory or service use for
NORMAL
servicing. "NORMAL" is
OVERRIDE
recommended for safety.
NO
Trims water handling
YES
Liquid level control sensitivity.
High is for reverse osmosis
water or very pure water.
HIGH
Chart to correct for altitude for boiling point
in tank water temperature.
Suggested
[ft]
[m]
Setting[°F]
0
0
205
500
152
205
1000
305
200
2000
610
200
2500
762
200
3000
914
200
3500
1067
197
4000
1219
195
4500
1372
194
5000
1524
194
5500
1676
193
6000
1829
192
6500
1981
191
7000
2134
190
7500
2286
188
8000
2438
187
8500
2591
185
Notes
[Switchable Units]
[Switchable Units]
170°F after 1 hour of
inactivity
system for Flowjet
Boiling
Suggested
Boiling
point[°F]
Setting[°C]
point [°C]
212.0
96
100.0
211.0
96
99.5
210.1
93
98.9
208.1
93
97.8
207.2
93
97.3
206.2
93
96.8
205.3
92
96.3
204.3
91
95.7
203.4
90
95.2
202.4
90
94.7
201.5
89
94.2
200.6
89
93.6
199.6
88
93.1
198.7
87
92.6
197.8
86
92.1
196.9
86
91.6
196.0
85
91.1
X
T
S
X
T
S
E
E
X
X
T
T
R
R
A
A
C
C
T
T
O
O
R
R
T
O
U
C
H
S
C
R
E
E
N
T
O
U
C
H
S
C
R
E
E
N
CBS_2100XTS
ECO
89
Heating
°C
Filling

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-2152xtsCbs-2152-2xtsCbs-2151xts

Table of Contents