LG DLHX4072W Owner's Manual page 24

Table of Contents

Advertisement

Available languages

Available languages

24
INSTALLATION INSTRUCTIONS
Connecting electric dryers (cont.)
USA only
WARNING
connected to the same color screw in block.
Failure to follow these instructions may result in
a short or overload.
grounding through the neutral conductor.
Four-wire connection for electric dryers:
Power cord
manufactured home installations, as well as all new
back of the dryer. Install a UL-listed strain relief into
the power cord through-hole; then thread a UL-listed,
conductor power cord through the strain relief.
UL-Listed
Cord
Terminal
UL-Listed
Strain Relief
forked terminals with upturned ends.
green ground screw to the center screw of the
terminal block. Attach the two hot leads of the power
cord to the outer terminal block screws.
Attach the white neutral wire to the center terminal
block screw. Attach the power cord ground wire to
the green ground screw.
Reinstall the terminal block access cover.
Neutral
Hot
Ground
Screw
Power Cord
Ground Wire
conductor and closed loop or
Hot
White Wire
moved from
Ground Screw