INSTALLATION INSTRUCTIONS
ASSEMBLY AND INSTALLATION (cont'd)
Check that the air conditioner is tilted downwards to the outside, about 3° to 4°, as shown in Fig. 7. After proper installa-
tion, condensed water should not drain from the overfl ow drain hole during normal use. If you notice water leaking out,
check the angle of tilt, and make any necessary adjustments. However, on a very humid day, water leakage can occur –
this is normal.
Note: To achieve 3° to 4°, you must measure the H, see fi gure 7.
Measure the tilt angle from the cabinet's edge. The distance H should be approximately 3/4 in. to 1 in. (19 mm - 2.5 cm)
for the unit.
OPERATING INSTRUCTIONS
KEY PAD FEATURES
TEMP/ TIMER
CONTROL
CHECK
FILTER
MODE
SELECTOR
ENERGY
SAVER
Fig. 7
Measure the tilt angle from the cabinet's edge
WINDOW
LED
DISPLAY
AUTO
TIMER
SLEEP
MODE
FAN
SPEED
POWER
BUTTON
: approximately 3/4 in. (19 mm) to
1 in. (2.5 cm) for
DAC060ECB4GDB
: approximately 1 in. (2.5 cm) to
1 3/8 in. (3.5 cm) for
LED DISPLAY: Displays the following information inde-
pendently - Set Temperature, Ambient RoomTemperature
and Auto Timer On/Off settings.
POWER: Turns unit On/Off.
MODE: Allows you to scroll through and select the desired
operating mode: Cool, Dry, Fan Only and *Auto. The select-
ed mode will be denoted by the adjacent indicator light.
*Auto mode is a pre-set factory program that automatical-
ly defi nes the mode (Cool or Dry) and fan speed, based
on the set temperature. The unit will automatically launch
the Energy Saver function when it is in Cool, Dry, or Auto
modes.
FAN SPEED: Select from four different fan settings: Low,
Medium, High and Auto during Cool and Fan Only mode.
Please note, during Dry mode the fan speed is automatical-
ly defi ned.