Initializing The System By Short-Circuiting; Basic Operations - Samsung SSA-S1000V User Manual

Standalone rfid access controller
Table of Contents

Advertisement

system initialization & basic operations

INITIALIZING THE SYSTEM BY SHORT-CIRCUITING

1.
Turn off the product and short-circuit three lines: white line of
the door lock device, green line of the Exit button, and yellow
line of the lock type.
2.
When you turn the product back on, all of the LED indicators
turn red or green, repeat turning on/off twice before being
completely turned off.
3.
In the power-off condition, all LED indicators turn green
bottom up in sequence.
4.
When you hear a beep 4 times, that indicates that the
initialization is completed.
M
If you initialize the system, all of the data settings will return to the factory default.

BASIC OPERATIONS

When the power is supplied
1.
All of the LED indicators will turn red or green, and repeat turning ON/OFF twice before being completely turned
OFF. In the power-off condition, all LED indicators turn red bottom up in sequence.
2.
You will hear a beep once.
When you present a registered card to the product or press the Exit button
1.
All LED indicators turn from red to green, and turn off top down in sequence before turning back red.
2.
Then, the door stays open for the specifi ed time with the upper one indicators turning green, which indicates the
door is open.
3.
You will hear a beep once.
When you present an unregistered card to the product
1.
All LED indicators turn red, and repeat turning on/off twice before staying in ON.
2.
You will hear a beep twice.
When you present a user card to the product while the door is open
1.
The one LED indicators from the top stay green, indicating the door is open; in the mean time, the other
indicators refl ect the authentication results.
Short-Circuit
White
Door Lock
Green
Exit Button
Yellow
Lock Type
Black
Power
Red