Vanguard BHDV37NA Owner's Operation And Installation Manual page 17

Direct-vent fireplace
Table of Contents

Advertisement

FIREPLACE
INSTALLATION
Continued
8. Plug in blower power cord.
a. If your fireplace system is installed
as a freestanding unit with an ac-
cessory mantel, determine whether
the power cord will exit the left side
or the right side of the firebox. In-
stall one plastic bushing provided
1
into the 1
/
" hole in the outer cas-
2
ing through which the power cord
will exit. Install the second plastic
bushing provided into the floor sup-
port bracket if exiting through the
right side (see Figure 34). Route
power cord through (both) plastic
bushing(s) and plug the power cord
into a properly grounded 3-prong
wall receptacle near the firebox.
b. If your fireplace system installation
is recessed and/or pre-wired, a
qualified installer must make all elec-
trical connections for the outlet kit
included with the fireplace.
Lower Rear
Wall of
Firebox
Wrapper
Lower Louver
Blower
Panel
Screws
Figure 31 - Mounting Blower to Firebox
105540
9.
Check to make sure that the power cord
is completely clear of the blower wheel
and that there are no other foreign ob-
jects in blower wheel. Turn blower on
and check for operation. Turn blower
off by rotating knob fully counterclock-
wise before continuing.
WARNING: Never touch the
blower wheel while in operation.
10. Peel off the backing paper and stick the
supplied wiring diagram decal on the
firebox bottom approximately 3" to the
right of the blower speed control
bracket (see Figure 34).
Figure 32 - Locating Thermal Switch Against Back of Firebox
Speed
Control
Control
Knob
Locknut
Figure 33 - Attaching Speed Control to Firebox
Exhaust Port
Top
Mounting
Tab
Blower
Speed
Control
Bracket
Figure 34 - Installing Plastic Bushing and Wiring Diagram Sticker
OWNER'S MANUAL
Thermal Switch
Control Shaft
Wiring
Diagram
17
WARNING: Failure to position
the parts in accordance with sup-
plied diagrams or failure to use
only parts specifically approved
with this heater may result in dam-
age or personal injury.
11. Connect or reconnect gas supply to fire-
place per Connecting Fireplace to Gas
Supply on page 19 of this manual.
NOTICE: A qualified service per-
son must connect fireplace to
gas supply. Follow all local codes.
Firebox
Bottom
Thermal
Switch
Side View
Plastic
Bushing
Firebox Back
Firebox Flange
Blower
Continued

Advertisement

Table of Contents
loading

Table of Contents