Control Panel Leds; Power Fail; Information Led - Supero SuperServer 6028R-TR User Manual

Table of Contents

Advertisement

SUPERSERVER 6028R-TR/TRT User's Manual
3-3

Control Panel LEDs

The control panel located on the front of the chassis has several LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any corrective
action you may need to take.

Power Fail

Indicates a power supply module has failed. The second power supply module will
take the load and keep the system running but the failed module will need to be
replaced. Refer to Chapter 6 for details on replacing the power supply. This LED
should be off when the system is operating normally.

Information LED

This LED will be solid blue when the UID function has been activated. When this
LED flashes red, it indicates a fan failure. When red continuously it indicates an
overheat condition, which may be caused by cables obstructing the airflow in the
system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain flashing
or on as long as the indicated condition exists.
State
Continuously On (Red)
Fast Blinking Red (1 Hz)
Slow Blinking Red (.25 Hz)
Solid Blue
Blinking Blue
Note: deactivating the UID LED must be performed in the same way it was activated.
(If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and
not with the UID button.)
Information LED States
Indication
An overheat condition has occured.
Fan Failure
Power Fail
Local UID button has been activated.
IPM/Remote UID has been activated
3-2