Supero SuperServer 6026TT-GTRF User Manual

Gpu-ready, 2u twin (two serverboards/nodes in a 2u chassis) rackmount server
Table of Contents

Advertisement

Quick Links

S
®
UPER
SuperServer 6026TT-GTRF
SuperServer 6026TT-GIBXRF
SuperServer 6026TT-GIBQRF
USER'S MANUAL
Revision 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Supero SUPERO SuperServer 6026TT-GTRF

  • Page 1 ® UPER SuperServer 6026TT-GTRF SuperServer 6026TT-GIBXRF SuperServer 6026TT-GIBQRF USER’S MANUAL Revision 1.0...
  • Page 2 This product, including software and docu- mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
  • Page 3: About This Manual

    Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6026TT-GTRF/ GIBXRF/GIBQRF. Installation and maintenance should be performed by experi- enced technicians only. The SuperServer 6026TT-GTRF/GIBXRF/GIBQRF is a GPU-ready, 2U Twin (two serverboards/nodes in a 2U chassis) rackmount server based on the SC827HD- R1400B server chassis and four Super X8DTT-HF+/X8DTT-HIBXF+/X8DTT-...
  • Page 4 SUPERSERVER 6026TT-GTRF/HDIBXRF/HDIBQRF User's Manual Chapter 3: System Interface Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system. Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the...
  • Page 5 Preface Notes...
  • Page 6: Table Of Contents

    2U Twin: System Notes ................... 1-6 Nodes ......................1-6 System Power ....................1-6 SATA Backplane/Drives ................... 1-6 GPU Subsystem ....................1-6 Contacting Supermicro ..................1-7 Chapter 2 Server Installation Overview ......................2-1 Unpacking the System ..................2-1 Preparing for Setup ..................2-1 Choosing a Setup Location ................
  • Page 7 Table of Contents Reliable Ground ..................2-3 Removing the Protective Film ................. 2-4 Rack Mounting Instructions ................2-5 Separating the Sections of the Rack Rails ............. 2-5 Installing the Inner Rail Extensions ..............2-6 Outer Rack Rails ..................... 2-7 Checking the Serverboard Setup ..............2-9 Preparing to Power On .................
  • Page 8 SUPERSERVER 6026TT-GTRF/HDIBXRF/HDIBQRF User's Manual 5-10 Serial ATA Ports .................... 5-19 5-11 Installing Additional Drivers ................5-20 5-12 Confi guring Supero Doctor III ............... 5-21 Chapter 6 Advanced Chassis Setup Static-Sensitive Devices .................. 6-1 Precautions ..................... 6-1 Unpacking ....................... 6-1 Control Panel ....................6-2 System Fans ....................
  • Page 9: Chapter 1 Introduction

    SC827HD-R1400B 2U chassis and two X8DTT-HF+/X8DTT-HIBXF+/X8DTT- HIBQF+ serverboards. Please refer to our web site for information on operating systems that have been certifi ed for use with the server (www.supermicro.com). In addition to the serverboard and chassis, various hardware components may have been included with the system, as listed below.
  • Page 10: Serverboard Features

    Processors Each X8DTT-HF+/X8DTT-HIBXF+/X8DTT-HIBQF+ supports two Intel® 5600/5500 Series processors in LGA1366 sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com). Memory Each X8DTT-HF+/X8DTT-HIBXF+/X8DTT-HIBQF+ has twelve DIMM sockets that can support up to 192 GB of registered ECC DDR3-1333/1066/800 SDRAM, or 48 GB of Unbuffered ECC/Non-ECC 1333/1066/800 MHz memory.
  • Page 11: Onboard Controllers/Ports

    Chapter 1: Introduction Onboard Controllers/Ports Onboard I/O backpanel ports on each serverboard include one COM port, a VGA port, two USB ports, a dedicated IPMI LAN port and two Gigabit LAN (NIC) ports. An Infi niBand port is also included on the X8DTT-HIBXF+/HIBQF+ serverboards (the 6026TT-GIBXRF and 6026TT-GIBQRF only).
  • Page 12 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual PROCESSOR#0 PROCESSOR#1 Intel 82574 MT25408 Connect-X IB QSFP PCI-E Gen2/DDR or QDR (For 36D Only) Intel 5520/5500 82574 36-D/24-D PCI-E x16 Slot AT25 DF321 ICH10R 4 SATA Hotswap Connector LPCIO W83527 BMC/VGA RMII VGA CONN RTL8201N PHY Dedicated LAN Figure 1-1.
  • Page 13: Server Chassis Features

    Chapter 1: Introduction Server Chassis Features The following is a general outline of the main features of the SC827HD-R1400B 2U chassis. Details on the chassis can be found in Chapter 6. System Power When confi gured as a SuperServer 6026TT-GTRF/GIBXRF/GIBQRF, the SC827HD- R1400B includes a redundant (dual) 1400W power supply, which provides power to all four serverboards (nodes).
  • Page 14: Twin: System Notes

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual 2U Twin: System Notes As a 2U Twin confi guration, the 6026TT-GTRF/GIBXRF/GIBQRF is a unique server system. With two system boards incorporated into a single chassis acting as two separate nodes, there are several points you should keep in mind. Nodes Each of the two serverboards act as a separate node in the system.
  • Page 15: Contacting Supermicro

    Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 16 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Notes...
  • Page 17: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get the 6026TT-GTRF/GIBXRF/ GIBQRF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled.
  • Page 18: Choosing A Setup Location

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Choosing a Setup Location • Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). • Leave approximately 30 inches of clearance in the back of the rack to allow for suffi...
  • Page 19: Rack Mounting Considerations

    Chapter 2: Server Installation • Allow the hot plug SATA drives and power supply modules to cool before touch- ing them. • Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling. •...
  • Page 20: Removing The Protective Film

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Removing the Protective Film Before operating the server for the fi rst time, it is important to remove the protec- tive fi lm covering the top of the chassis, in order to allow for proper ventilation and cooling.
  • Page 21: Rack Mounting Instructions

    Chapter 2: Server Installation Rack Mounting Instructions This section provides information on installing the SC827 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
  • Page 22: Installing The Inner Rail Extensions

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Installing the Inner Rail Extensions The SC827 chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached to the chassis, and do not interfere with normal use of the chassis if you decide not to use a server rack. The inner rail extension is attached to the inner rail to mount the chassis in the rack.
  • Page 23: Outer Rack Rails

    Chapter 2: Server Installation Figure 2-4: Assembling the Outer Rails Outer Rack Rails Outer rails attach to the rack and hold the chassis in place. The outer rails for the SC827 chassis extend between 30 inches and 33 inches. Installing the Outer Rails to the Rack Secure the back end of the outer rail to the rack, using the screws provided.
  • Page 24 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Figure 2-5: Installing Into the Rack Installing the Chassis into a Rack Extend the outer rails as illustrated above. Align the inner rails of the chassis with the outer rails on the rack. Slide the inner rails into the outer rails, keeping the pressure even on both sides.
  • Page 25: Checking The Serverboard Setup

    Chapter 2: Server Installation Checking the Serverboard Setup After you install the system in the rack, you will need to access the inside of the nodes to make sure the serverboard is properly installed. Accessing the Inside of a Node (Figure 2-6) Before removing a node, unplug all the cables that connect to that node.
  • Page 26: Preparing To Power On

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Preparing to Power On Next, you should check to make sure the SATA drives and the backplane have been properly installed and all connections have been made. Checking the SATA drives The SATA disk drives are accessable from the front of the server and can be installed and removed from the front of the chassis without removing the top chassis cover.
  • Page 27 Chapter 2: Server Installation Figure 2-6. Removing a Node from the System 2-11...
  • Page 28 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Notes 2-12...
  • Page 29: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are LEDs on the control panels and on the SATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi...
  • Page 30: Control Panel Leds

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Control Panel LEDs In addition to the LEDs built into the power and UID buttons, each of the four control panels located on the front of the SC827HD-R1400B chassis has two LEDs that provide you with critical information related their own node. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
  • Page 31: Chapter 4 System Safety

    Chapter 4: System Safety Chapter 4 System Safety Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6026TT-GTRF/GIBXRF/GIBQRF from damage: • Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet.
  • Page 32: General Safety Precautions

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual • This product may be connected to an IT power system. In all cases, make sure that the unit is also reliably connected to Earth (ground). • Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 4-1).
  • Page 33: Esd Precautions

    Chapter 4: System Safety • Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. •...
  • Page 34: Operating Precautions

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Operating Precautions Care must be taken to assure that the chassis cover is in place when the 6026TT- GTRF/GIBXRF/GIBQRF is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed. Figure 4-1.
  • Page 35: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install the X8DTT-HF+/X8DTT-HIBXF+/ X8DTT-HIBQF+ serverboard into the SC827HD-R1400B chassis, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described.
  • Page 36: I/O Ports

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Unpacking The serverboard is shipped in antistatic packaging to avoid electrostatic discharge. When unpacking the board, make sure the person handling it is static protected. I/O Ports The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-1 below for the colors and locations of the various I/O ports.
  • Page 37: Processor And Heatsink Installation

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro web site for updates on CPU support. Installing LGA1366 Processors Starting with CPU1, press the...
  • Page 38 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual After removing the plastic cap, use your thumb and the index fi nger to hold the CPU at the north and south center edges. Align the CPU key (the semi-circle cutout) with the socket key (the notch below the gold color dot on the side of the socket).
  • Page 39: Installing A Cpu Heatsink

    Chapter 5: Advanced Serverboard Setup Installing a CPU Heatsink Remove power from the system and unplug the AC power cord from the power supply. Do not apply any thermal grease Screw #1 Screw #2 to the heatsink or the CPU die; the required amount has already been applied.
  • Page 40: Removing The Heatsink

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Removing the Heatsink Warning! We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the heatsink, please follow the instructions below to prevent damage to the CPU or the CPU socket. Remove power from the system and unplug the AC power cord from the power supply.
  • Page 41: Installing Memory

    The X8DTT-H+ series serverboard supports up to 192 GB of registered ECC DDR3- 1333/1066/800 SDRAM, or 48 GB of Unbuffered ECC/Non-ECC 1333/1066/800 MHz memory. Note: Check the Supermicro web site for recommended DIMMs. Installing Memory Modules Insert each memory module vertically into a slot following the charts below.
  • Page 42 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual DIMM Population Table DIMM DIMMs DIMM Type (Reg.= Speeds (in MHz) Ranks per DIMM Slots per Populated Registered) (any combination; Channel per Channel SR=Single Rank, DR=Dual Rank, QR=Quad Rank) Reg. DDR3 ECC 800,1066,1333 SR or DR Reg.
  • Page 43: Adding Pci Cards

    Chapter 5: Advanced Serverboard Setup Possible System Memory Allocation & Availability System Device Size Physical Memory Remaining Physical Memory Remaining (Available) (Available) (3 GB Total System Memory) (4 GB Total System Memory) Firmware Hub 1 MB 3.00 3.99 fl ash memory (System BIOS) Local APIC 4 KB...
  • Page 44: Serverboard Details

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Serverboard Details Figure 5-3. X8DTT-H+ Series Serverboard Layout COM1 LAN2 LAN1 USB0/1 InfinBand JSPK1 IPMI_LAN Connector Winbond InfiniBand LAN CTRL1 CTRL WPCM450 LAN CTRL2 C384 JUSB2 JLPC80 JBT1 CLEAR CMOS Intel ICH10R South Bridge BIOS Intel 5520 (IOH-36D) Intel 5500 (IOH-24D) (For OEM only) Battery...
  • Page 45: Serverboard Quick Reference

    Chapter 5: Advanced Serverboard Setup Serverboard Quick Reference Jumper Description Default Setting JBT1 CMOS Clear (See Section 5-8) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1/JPL2 LAN1/2 Enable/Disable Pins 1-2 (Enabled) JWD1 Watch Dog Enable/Disable/Reset Pins 1-2 (Reset) Connector Description COM1 COM1 Serial Port FAN 1 Cooling Fan Header...
  • Page 46: Connector Defi Nitions

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Connector Defi nitions Front Panel Accessible Add-on Card Header (JF2) The JF2 add-on card header provides front access to the power supply, Serial ATA and Front Panel Control connections for the X8DTT-H Series serverboard. Plug an Add-On card into this header to use the functions indicated above.
  • Page 47 Chapter 5: Advanced Serverboard Setup Fan Header The X8DTT-H Series serverboard has one Fan Header fan header. This 4-pin header is backward Pin Defi nitions compatible with traditional 3-pin fans, how- Pin# Defi nition ever, fan speed control is only available for Ground 4-pin fans.
  • Page 48 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Ethernet Ports LAN Ports Pin Defi nitions Two Ethernet ports are located next to Pin# Defi nition Pin# Defi nition USB0/1 on the IO backplane. In addition, P2V5SB SGND an IPMI Dedicated LAN is located above TD0+ Act LED USB0/1.
  • Page 49 Chapter 5: Advanced Serverboard Setup Serial Ports Serial Port Pin Defi nitions Pin Defi nitions One serial port is included on the serverboard. Pin # Defi nition Pin # Defi nition The COM port is located beside the VGA port. See the table on the right for pin defi ni- tions.
  • Page 50: Jumper Settings

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Jumper Settings Connector To modify the operation of the serverboard, Pins jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function Jumper of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board.
  • Page 51 Chapter 5: Advanced Serverboard Setup LAN1/LAN2 Enable/Disable LAN1/2 Enable/Disable Jumper Settings Change the setting of jumper JPL1/JPL2 Jumper Setting Defi nition to enable or disable the LAN1 and LAN2 Pins 1-2 Enabled ports respectively. See the table on the right Pins 2-3 Disabled for jumper settings.
  • Page 52: Onboard Indicators

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Onboard Indicators LAN1/LAN2 LEDs LAN1/LAN2 LEDs (Connection Speed The Ethernet ports (located beside the COM Indicator) port) have two LEDs. On each Gb LAN port, LED Color Defi nition one LED indicates activity when blinking No connection or while the other LED may be green, amber or 10 Mb/s off to indicate the speed of the connection.
  • Page 53: 5-10 Serial Ata Ports

    Chapter 5: Advanced Serverboard Setup BMC Activity LED (LE2) A BMC Heartbeat LED is located at LE2 BMC Heartbeat LED on the serverboard. When LE2 is on, BMC BMC is normal (Baseboard Management Controller) is active. See the table at right for more in- formation.
  • Page 54: 5-11 Installing Additional Drivers

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual 5-11 Installing Additional Drivers After you've installed the Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items.
  • Page 55: Confi Guring Supero Doctor Iii

    Chapter 5: Advanced Serverboard Setup 5-12 Confi guring Supero Doctor III The Supero Doctor III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called the SD III Client. The Supero Doctor III program included on the CDROM that came with your serverboard allows you to monitor the environment and operations of your system.
  • Page 56 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Note: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp:// ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you use Supero Doctor II.
  • Page 57: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform main- tenance on the SC827HD-R1400B chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 58: Control Panel

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Figure 6-1. Chassis Front View Node A Control Panel Node B Control Panel SATA Drives Figure 6-2. Chassis Rear View Dedicated IPMI LAN Port Dedicated IPMI LAN Port LAN Ports PCI-Express x16 Card (1) Power Supply LAN Ports PCI-Express x16 Card (1) USB Ports COM Port VGA Port...
  • Page 59: Fan Confi Guration

    Chapter 6: Advanced Chassis Setup Fan Confi guration In the 2U Twin, each node (serverboard) controls the two fans that reside on its side of the chassis. System Fan Failure If a fan fails, the remaining fans will ramp up to full speed and the overheat/fan fail LED on the control panel will blink on and off (about once per second).
  • Page 60: Hard Drive Installation/Removal

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Hard Drive Installation/Removal Overview The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the system. For this reason, even empty carriers without drives installed must remain in the chassis.
  • Page 61 Swing the handle fully out and use it to pull the unit straight out (see Figure 6-5). Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/storage.
  • Page 62 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Figure 6-5. Removing a Hard Drive Figure 6-6. Drives and Nodes: Logical Confi guration Note: see Figure 6-1 for the locations of the control panels that are associated with each node.
  • Page 63: Node Installation/Removal

    Chapter 6: Advanced Chassis Setup Node Installation/Removal As with any server system, power must be removed from the serverboard when upgrading or installing memory or processors. In the 2U Twin server, the server- boards (nodes) are capable of being hot-swapped from the chassis, allowing one to be powered down for servicing while the other continues operating.
  • Page 64 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Figure 6-7. Removing a System Node...
  • Page 65: Installing The Air Shrouds

    A will fl ash slowly (about 4 seconds on and 4 off) and remain fl ashing until the failed unit has been replaced. Replacement units can be ordered directly from Supermicro (see contact information in the Preface). The power supply units have a hot-swap capability, meaning you can replace the failed unit without powering down the system.
  • Page 66 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Figure 6-8. Removing the Power Supply Release Tab 6-10...
  • Page 67: Chapter 7 Bios

    When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.) The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys".
  • Page 68: Starting The Setup Utility

    Warning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating.
  • Page 69 Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.) Supermicro X8DTT/-F/-IBX/-IBXF/-IBQ/-IBQF BIOS Build Version This item displays the BIOS revision used in your system.
  • Page 70: Advanced Setup Confi Gurations

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Advanced Setup Confi gurations Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items: BOOT Features Quick Boot If Enabled, this option will skip certain tests during POST to reduce the time needed for system boot.
  • Page 71: Processor And Clock Options

    Chapter 7: BIOS Hit 'Del' Message Display This feature displays "Press DEL to run Setup" during POST. The options are Enabled and Disabled. Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture"...
  • Page 72 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual C1E Support Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by reducing the CPU's clock cycle and voltage during a "Halt State." The options are Disabled and Enabled. Hardware Prefetcher (Available when supported by the CPU) If set to Enabled, the hardware pre fetcher will pre fetch streams of data and instruc- tions from the main memory to the L2 cache in the forward or backward manner to...
  • Page 73: Advanced Chipset Control

    Chapter 7: BIOS tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Enable (Enable GV3). Intel® TurboMode Technology Select Enabled to use the Turbo Mode to boost system performance. The options are Enabled and Disabled.
  • Page 74 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual QPI L0s and L1 This enables the QPI power state to low power. L0s and L1 are automatically selected by the motherboard. The options are Disabled and Enabled. Memory Frequency This feature forces a DDR3 frequency slower than what the system has detected. The available options are Auto, Force DDR-800, Force DDR-1066, and Force DDR-1333.
  • Page 75 Chapter 7: BIOS Throttling - Closed Loop/Throttling - Open Loop Throttling improves reliability and reduces power in the processor by automatic voltage control during processor idle states. Available options are Disabled and Enabled. If Enabled, the following items will appear: Hysteresis Temperature Temperature Hysteresis is the temperature lag (in degrees Celsius) after the set DIMM temperature threshold is reached before Closed Loop Throttling...
  • Page 76 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual North Bridge Confi guration This feature allows the user to confi gure the settings for the Intel IOH chip. Crystal Beach/DMA (Direct Memory Access) This feature works with the Intel I/O AT (Acceleration Technology) to accelerate the performance of TOE devices.
  • Page 77 Chapter 7: BIOS USB 2.0 Controller Select Enabled to activate the onboard USB 2.0 controller. The options are Enabled and Disabled. USB 2.0 Controller Mode This setting allows you to select the USB 2.0 Controller mode. The options are Hi-Speed (480 Mbps) and Full Speed (12 Mbps). BIOS EHCI Hand-Off Select Enabled to enable BIOS Enhanced Host Controller Interface support to provide a workaround solution for an operating system that does not have EHCI...
  • Page 78 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Hot Plug (This feature is available when the option-Enabled is selected) Select Enable to enable the hot plug function for the SATA devices. The options are Enabled and Disabled. SATA#2 Confi guration Selecting Enhanced will set SATA#2 to native SATA mode. The options are Disabled, and Enhanced.
  • Page 79 Chapter 7: BIOS Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MBs. Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate of 5.2 MBs.
  • Page 80 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Select UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer rate of 133 MBs. Select UDMA6 to allow the BIOS to use Ultra DMA mode 6. It has a data transfer rate of 133 MBs.
  • Page 81 Chapter 7: BIOS Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM Select Enabled to enable the onboard LAN1 or LAN2 Option ROM. This is to boot computer using a network interface. The options are Enabled and Disabled. Super IO Device Confi guration Serial Port1 Address/ Serial Port2 Address This option specifi...
  • Page 82: Hardware Health Monitor

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Terminal Type This feature allows the user to select the target terminal type for Console Redirec- tion. The options are ANSI, VT100, and VT-UTF8. VT-UTF8 Combo Key Support A terminal keyboard defi nition that provides a way to send commands from a remote console.
  • Page 83 ‘Temperature Tolerance’ is, and not the other way around. This results in better CPU thermal management. Supermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium and High). This makes it easier for the user to understand the CPU’s temperature status, rather than by just simply...
  • Page 84 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual User intervention: If the system buzzer and Overheat LED has activated, take action immediately by checking the system fans, chassis ventilation and room temperature to correct any problems. Notes: The system may shut down if it continues for a long period to prevent damage to the CPU.
  • Page 85 Chapter 7: BIOS APIC ACPI SCI IRQ When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system. The options are Enabled and Disabled. Headless Mode This feature is used to enable system to function without a keyboard, monitor or mouse attached The options are Enabled and Disabled.
  • Page 86 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual View BMC System Event Log This feature displays the BMC System Event Log (SEL). It shows the total num- ber of entries of BMC System Events. To view an event, select an Entry Number and pressing <Enter> to display the information as shown in the screen. •...
  • Page 87 Chapter 7: BIOS IP Address Source Select the source of this machine's IP address. If Static is selected, you will need to know and enter manually the IP address of this machine below. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Confi guration Protocol) server in the network it is attached to, and request the next available IP address.
  • Page 88 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Subnet Mask This item displays the current subnet mask setting for your IPMI connection. Current Subnet Mask in BMC This item displays the current subnet mask used for your IPMI connection. Gateway Address Confi guration Enter the gateway address for this machine. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
  • Page 89: Security Settings

    Chapter 7: BIOS DMI Event Log View Event Log Use this option to view the System Event Log. Mark all events as read This option marks all events as read. The options are OK and Cancel. Clear event log This option clears the Event Log memory of all messages. The options are OK and Cancel.
  • Page 90: Boot Confi Guration

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Password Check This item allows you to check a password after it has been entered. The options are Setup and Always. Boot Sector Virus Protection When Enabled, the AMI BOIS displays a warning when any program (or virus) is- sues a Disk Format command or attempts to write to the boot sector of the hard disk drive.
  • Page 91 Chapter 7: BIOS Hard Disk Drives This feature allows the user to specify the boot sequence from all available hard disk drives. The settings are Disabled and a list of all hard disk drives that have been detected (i.e., 1st Drive, 2nd Drive, 3rd Drive, etc). •...
  • Page 92: Exit Options

    Warning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you need to update the BIOS, do not shut down or reset the system while the BIOS is updating.
  • Page 93: How To Recover The Amibios Image (The Main Bios Block)

    Note: BIOS Recovery described below is used when the main BIOS block crashes. However, when the BIOS Boot sector crashes, you will need to send the mother- board back to Supermicro for RMA repairs. Boot Sector Recovery from a USB Device This feature allows the user to recover a BIOS image using a USB device without additional utilities needed.
  • Page 94: Boot Sector Recovery From A Serial Port ("Serial Flash")

    SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Boot Sector Recovery from a Serial Port ("Serial Flash") This process, also known as "Serial Flash," allows the user to use a serial port to load a BIOS image for Boot Sector recovery. This feature is usually used for embed- ded systems that rely on a serial port for remote access and debugging.
  • Page 95 Chapter 7: BIOS 4. Power on your system and click the <Connect> button in the Hyper Terminal. The terminal screen will display the following messages. 5. Following the instructions given on the screen to update the BIOS. These instructions are also shown below. a.
  • Page 96 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual 6. Once you've completed the instructions given, a screen will display to indicate that remote fl ashing is starting and the new BIOS fi le is being uploaded. 7. To use Hyper Terminal to transfer the XModem protocol by using the "Send File"...
  • Page 97: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 98 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Notes...
  • Page 99: Appendix B Installing Windows

    South Bridge RAID Settings before you install the Windows OS and other software drivers. To confi gure RAID settings, please refer to RAID Confi guration User Guides posted on our web site at www.supermicro.com/support/manuals. B-1 Installing Windows for a RAID System Insert Microsoft's Windows XP/2003 Setup CD in the CD drive and the system will start booting up from CD.
  • Page 100: B-2 Installing Windows For A Non-Raid System

    Windows XP/2003 installation. After the Windows XP/2003 OS Installation is completed, the system will automatically reboot. Insert the Supermicro Setup CD that came with your motherboard into the CD Drive during system boot, and the main screen will display.
  • Page 101 Appendix C: System Specifi cations Appendix C System Specifi cations Note: unless noted specifi cations apply to a complete system (two serverboards). Processors Four Intel® 5600/5500 Series processors in LGA1366 sockets Note: Please refer to our website for details on supported processors. Chipset Intel 5500/ICH10R (X8DTT-HF+) Intel 5520/ICH10R (X8DTT-HIBXF+, X8DTT-HIBQF+)
  • Page 102 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual Serverboard 6026TT-GTRF: X8DTT-HF+ 6026TT-GIBXRF: X8DTT-HIBXF+ 6026TT-GIBQRF: X8DTT-HIBQF+ Dimensions (all): 16.64" (L) x 6.80" (W) (422.66 mm x 172.72 mm) Chassis SC827HD-R1400B (2U Rackmount) Dimensions: (WxHxD) 17.2 x 3.5 x 28.5 in. (437 x 89 x 724 mm) Weight Gross Weight: 85 lbs.
  • Page 103 Appendix C: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/- 3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials:...
  • Page 104 SUPERSERVER 6026TT-GTRF/GIBXRF/GIBQRF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...

This manual is also suitable for:

Superserver 6026tt-gibqrfSuperserver 6026tt-gibxrf

Table of Contents