REAR PANEL

20
19
18
17
16
14
13
15
5
For 220-240VAC operation a fuse rated at 1.6 amps and 250V should be used, which conforms to the
international fuse classification "T1.6AL".
If the unit continues to blow replacement fuses, do not keep replacing them, it should be taken to a qualified
service center for repair.
To replace the fuse, be sure to remove the IEC power cord from the IEC socket. The fuse holder tray is located
beneath the IEC socket cavity. Pry the fuse holder tray out with a small flat blade screwdriver placed under the
center of the top edge of the fuse tray, and gently lever the fuse tray out. The fuse is held in a clip in the fuse tray,
and should be removed and replaced with a fresh 5 X 20mm 250V type fuse of the appropriate current rating.
VOLTAGE SELECTION PROCESS
CAUTION:Always disconnect AC power cord from unit, or AC power
source before attempting to change fuse/voltage selector position!
WARNING!: Before AC power is applied to this device,
always insure proper operating voltage selection is
engaged to match AC power source being used.
21
voltage selection (2) may select 110-120V AC or 220-240V AC
The fuse should be changed to the correct amperage rating. For
12
an input power voltage range of from 110VAC to 120VAC, use a 3.15
amp rated, 250V 5 x 20 mm cartridge type time-delay fuse, which
11
conforms to the international fuse classification "T3.15AL". For
an input power voltage range of from 220VAC to 240VAC, use a 1.6
10
8
amp rated, 250V 5 x 20 mm cartridge type time-delay fuse,
7
which conforms to the international fuse classification "T1.6AL".
9
The IEC power cord that is correct for your locale can now be
plugged into the IEC receptacle (3), and the Power switch (1)
6
activated to turn on the powered PBK15FM speaker system.
ON-OFF SWITCH (1)
This rocker switch supplies AC power to the PBK15FM when
switched to the ON position. The ON position is with the top side
of the switch pushed "in" or nearly flush with the rear panel.
FUSE (2)
4
The unit is AC power line fuse protected from overloads
and fault conditions with a slow-blow 5 x 20mm 250V fuse.
This fuse is located within the base of the IEC power cord
connector (2), just below the IEC connector blades. If the fuse
2
fails, THE FUSE MUST BE REPLACED WITH THE SAME TYPE AND
VALUE IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT AND TO
1
PREVENT VOIDING THE WARRANTY!
The fuse in the Peavey PBK15FM can be replaced with a time-
3
delay type 5 x 20 mm size 250V rated fuse.
For 110-120VAC operation, a fuse rated at 3.15 amps
and 250V should be used, which conforms to the
international fuse classification "T3.15AL".